|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TFS70S.doc Version 1.2 06.01.02 VI TELEFILTER Filter Specification TFS 70 S 1/3 1. Measurement condition 23 C 0 dBm. for input: for output: Ambient temperature TA: Input power level: Terminating impedances in fc: 50 - 39,16 pF. 50 - 39,16 pF. 2. Characteristics Remark: Reference level for the relative attenuation arel of the TFS 70S is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at the 40 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme. Data Insertion loss (Reference level) ae typ. value 21 70 dB MHz tolerance / limit max 24 70 0,1 dB MHz Reference frequency fc at ambient temperature (fCAT) Pass band ( PB ) : Bandwidth at ambient temperature: 1,0 3,0 20 40 45 50 dB - band width dB - band width dB - band width dB - band width dB - band width dB - band width fC - 5,2 MHz ... fC + 5,2 MHz 10,75 10,90 11,37 11,57 11,60 11,62 0,7 MHz MHz MHz MHz MHz MHz dB min. 10,4 min. 10,8 max. 11,6 MHz MHz MHz Amplitude ripple in pass band (p-p) : Relative attenuation fc fc fc fc fc + fc 5,2 5,8 6,4 65 35 MHz MHz MHz MHz MHz ... ... ... ... ... ... fc fc fc fc fc fc arel + 5,2 5,4 6,4 35 35 65 MHz MHz MHz MHz MHz MHz max. 1 dB 0,7 2 45 55 75...60 60...65 3,71 110 dB dB dB dB dB dB s ns max 1 max 3 min 40 min 45 min 55 min 55 max 4,2 max 200 dB dB dB dB dB dB s ns Average group delay in PB : Group delay ripple in PB (p-p) : Deviation from linear phase in PB : Triple transit attenuation compared to main signal Crosstalk Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature Operating temperature range Storage temperature range 5,5 p-p...( 0,86 r.m.s.) 50 55...70 -87 dB dB ppm/K -94 ppm/K fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz) - 25 C ... + 85 C - 25 C ... + 85 C Generated: Wadim P. Dunzow Checked/Approved: Dr. Bert Wall VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS70S.doc Version 1.2 06.01.02 VI TELEFILTER Filter Specification TFS 70 S 2/3 3. Package 35 Max Pin 23 Pin 24 Pin 11 Pin 12 Pin 4-9, 16-21 Pin 1-3, 10, 13-15, 22 Input Input RF Return Output Output RF Return Ground not connected 20,5 Max TFS 70 S tft L0 5,5 5,5 12 3 10 11 12 15,24 24 23 22 13 2,54 11x2,54 = 27,94 4. 50 matching network: 1 50 11 12 Scheme 1. L2 L4 50 L3 L1 24 23 13 L1 = L2 =220 nH. L3 = L4 =330 nH - have to be adjusted (for example: 270, 330, 390 nH ). 1 50 11 12 Scheme 2. L2 C2 50 C1 L1 24 23 13 L1 = L2 =100 nH. C1 = C2 =12,54 pF - have to be adjusted (for example: 10, 12, 15 pF ). For final test in production we use matching network 1. VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS70S.doc Version 1.2 06.01.02 VI TELEFILTER Filter Specification TFS 70 S 3/3 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS70S |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |