![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Filename: TFS1150A.doc Version 1.4 06.01.2004 VI TELEFILTER Measurement condition Ambient temperature: Input power level: Terminating impedance: Input: Output: 23 0 100 100 Development specification TFS1150 A 1/5 C dBm Characteristics Remark: The Reference level for the relative attenuation a rel of the TFS1150A is the minimum attenuation in the pass band. The minimum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1150 MHz without tolerance or limit. The values of relative attenuation arel are guaranteed in the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data Insertion loss Nominal frequency Passband Relative attenuation fN fN 5 8 0 1100 1120 1170 1180 1190 Group delay Group delay ripple within PB Operating temperature range Storage temperature range Temperature coefficient of frequency **) fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz). typ. value ae fN arel MHz MHz aabs MHz MHz MHz MHz (0...+ 80C) MHz MHz at fN tolerance / limit max. 2,7 1150 fN 5 dB MHz MHz MHz ... fN MHz ... fN MHz MHz MHz MHz MHz MHz ... ... ... ... ... ... + + 5 8 1100 1120 1130 1180 1190 1900 - max. max. min. min. min. min. min. min. 100 35 1 3 50 35 15 15 35 50 dB dB dB dB dB dB dB dB ns ns Absolute attenuation OTR TCf ** T.B.D ppm/K - 40 C ... + 85 C - 40 C ... + 85 C - Generated: Checked / Approved: Tele Filter GmbH Potsdamer Strae 18 D-14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS1150A.doc Version 1.4 06.01.2004 VI TELEFILTER Construction and pin configuration (All dimensions in mm) Development specification TFS1150 A 2/5 6 5 4 Date code: Year+week S T U ... B50A S02 1 2 3 date code 2004 2005 2006 1 3 Pin Pin Pin Pin Pin Pin 1 2 3 4 5 6 Input Input Ground Output Output Ground 0,6 6 4 0,6 Tele Filter GmbH Potsdamer Strae 18 D-14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS1150A.doc Version 1.4 06.01.2004 VI TELEFILTER Stability characteristics Development specification TFS1150 A 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 14 Test N reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: T.B.D Tele Filter GmbH Potsdamer Strae 18 D-14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS1150A.doc Version 1.4 06.01.2004 VI TELEFILTER Air reflow temperature conditions Development specification TFS1150 A 4/5 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods main-heating periods 150 C - 170 C over 200 C 60 sec. - 90 sec. 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / s ec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Tele Filter GmbH Potsdamer Strae 18 D-14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS1150A.doc Version 1.4 06.01.2004 VI TELEFILTER History Version 1.0 1.1 1.2 1.3 1.4 Reason of Changes Development specification TFS1150 A 5/5 Name Konietzko Wall Date 19.09.2003 24.09.2003 - Generation of development specification - Package drawing corrected. - Marking changed. - Change of fN 8 MHz specification, change of temperature range (1170 MHz 1180 MHz ) - Change of package - Change of passband from 8 to 5 MHz Roizengaft Roizengaft Roizengaft 16.12.2003 06.01.2004 06.01.2004 Tele Filter GmbH Potsdamer Strae 18 D-14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS1150A
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |