![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Micrel, Inc. TRIPLE DIFFERENTIAL 2:1 MULTIPLEXER SY10E457 SY100E457 SY10E457 SY100E457 FEATURES s Differential D and Q s Extended 100E VEE range of -4.2V to -5.5V s s s s s s VBB output for single-ended use 700ps max. propagation delay High frequency outputs Separate and common select Internal 75K input pulldown resistors Available in 28-pin PLCC package DESCRIPTION The SY10/100E457 are 3-bit differential 2:1 multiplexers. The fully differential data path makes the devices ideal for multiplexing low skew clock or other skew sensitive signals. Multiple VBB pins are provided to ease AC coupling input signals. The higher frequency outputs provide the device with a >1.0GHz bandwidth to meet the needs of the most demanding system clock. Both separate selects and a common select are provided to make the device well suited for both data path and random logic applications. BLOCK DIAGRAM PIN NAMES Pin Function Differential Data Inputs Individual Select Input Common Select Input VBB Reference Output Differential Data Outputs VCC to Output D0a D0a D0b D0b SEL0 H 2:1 MUX Q0 Q0 Dn[0:2], Dn[0:2] SEL COMSEL VBB Q[0:2], Q[0:2] VCCO L D1a D1a D1b D1b SEL1 H 2:1 MUX Q1 Q1 L D2a D2a D2b D2b SEL2 H 2:1 MUX Q2 Q2 L COMSEL VBB M9999-032206 hbwhelp@micrel.com or (408) 955-1690 Rev.: F Amendment: /0 1 Issue Date: March 2006 Micrel, Inc. SY10E457 SY100E457 PACKAGE/ORDERING INFORMATION D2b COMSEL Ordering Information(1) Part Number SY10E457JC 18 17 SEL2 D2a D2a VBB D2b Package Type J28-1 J28-1 J28-1 J28-1 J28-1 J28-1 J28-1 J28-1 Operating Range Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Package Marking SY10E457JC SY10E457JC SY100E457JC SY100E457JC SY10E457JZ with Pb-Free bar-line indicator SY10E457JZ with Pb-Free bar-line indicator SY100E457JZ with Pb-Free bar-line indicator SY100E457JZ with Pb-Free bar-line indicator Lead Finish Sn-Pb Sn-Pb Sn-Pb Sn-Pb Matte-Sn Matte-Sn Matte-Sn Matte-Sn 25 24 23 22 21 20 19 SEL1 D1a D1a VEE VBB D1b D1b 26 27 28 1 2 3 4 5 6 7 8 9 10 11 Q2 Q2 VCC Q1 Q1 Q0 Q0 SY10E457JCTR(2) SY100E457JC SY100E457JCTR(2) SY10E457JZ(3) SY10E457JZTR(2, 3) SY100E457JZ(3) SY100E457JZTR(2, 3) TOP VIEW PLCC J28-1 16 15 14 13 12 D0a 28-Pin PLCC (J28-1) Notes: SEL0 VCCO D0a VBB D0b D0b 1. Contact factory for die availability. Dice are guaranteed at TA = 25C, DC Electricals only. 2. Tape and Reel. 3. Pb-Free package is recommended for new designs. M9999-032206 hbwhelp@micrel.com or (408) 955-1690 2 Micrel, Inc. SY10E457 SY100E457 DC ELECTRICAL CHARACTERISTICS VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND TA = 0C Symbol VBB Parameter Output Reference Voltage 10E 100E Input HIGH Current Power Supply Current 10E 100E VPP (DC) VCMR Input Sensitivity Common Mode Range -- -- 50 -1.5 92 92 -- -- 110 110 -- 0 -- -- 50 -1.5 92 92 -- -- 110 110 -- 0 -- -- 50 -1.5 92 106 -- -- 110 127 -- 0 mV V 1 2 Min. -1.38 -1.38 -- Typ. -- -- -- Max. Min. TA = +25C Typ. -- -- -- Max. -1.25 -1.26 150 TA = +85C Min. Typ. -1.31 -1.38 -- -- -- -- Max. -1.19 -1.26 150 A mA -- -- Unit V -1.27 -1.35 -1.26 -1.38 150 -- Condition -- IIH IEE Notes: 1. Differential input voltage required to obtain a full ECL swing on the outputs. 2. VCMR is referenced to the most positive side of the differential input signal. Normal operation is obtained when the input signals are within the VCMR range and the input swing is greater than VPP (min.) and <1V. AC ELECTRICAL CHARACTERISTICS VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND TA = 0C Symbol tPD Parameter Propagation Delay to Output D (Diff) D SEL COMSEL Within-Device Skew Duty Cycle Skew tPLH-tPHL Minimum Input Swing Rise/Fall Time 20-80% Min. 375 325 350 375 -- -- 150 150 Typ. 475 475 500 525 40 10 -- 275 Max. 650 700 725 750 -- -- -- 450 TA = +25C Min. Typ. 375 325 350 375 -- -- 150 150 475 475 500 525 40 10 -- 275 Max. 650 700 725 750 -- -- -- 450 TA = +85C Min. Typ. 375 325 350 375 -- -- 150 150 475 475 500 525 40 10 -- 275 Max. 650 700 725 750 -- -- -- 450 ps ps mV ps 1 2 3 -- Unit ps Condition -- tskew tskew VPP (AC) tr tf Notes: 1. Within-device skew is defined as identical transitions on similar paths through a device. 2. Duty cycle skew guarantee holds only for differential operation when the delays are measured from the cross point of the inputs to the cross point of the outputs. 3. Minimum input swing for which AC parameters are guaranteed. M9999-032206 hbwhelp@micrel.com or (408) 955-1690 3 Micrel, Inc. SY10E457 SY100E457 28-PIN PLCC (J28-1) Rev. 03 MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 TEL USA + 1 (408) 944-0800 FAX + 1 (408) 474-1000 WEB http://www.micrel.com The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser's use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser's own risk and Purchaser agrees to fully indemnify Micrel for any damages resulting from such use or sale. (c) 2006 Micrel, Incorporated. M9999-032206 hbwhelp@micrel.com or (408) 955-1690 4 |
Price & Availability of SY10E45706
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |