 Current Transducer HAL 200-S
For the electronic measurement of DC, AC and pulsed currents, with a galvanic isolation between the primary (high power) circuit and the secondary (electronic) circuit.
IPN = 200 A
Electrical data
IPN IP IP VOUT RL VC IC Vb Vd Ris Primary nominal DC or rms current Primary current, measuring range Overload capacity (Ampere Turns) Analogue output voltage @ IPN Load resistance TA = 0 .. + 70C TA = - 25 .. + 85C Supply voltage ( 5 %) Current consumption (max) Rms rated voltage1) Rms voltage for AC isolation test, 50 Hz, 1 mn Isolation resistance @ 500 VDC 200 0 .. 600 30000 4 >1 >3 15 25 500 3 > 500 A A A V k k V mA V kV M
Features
* Open loop transducer using Hall
Effect
* Panel mounting - Horizontal or
Vertical
* Insulated plastic case to UL 94-V0.
Advantages
* * * * * *
Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference * Current overload capability * Low power consumption * Wide dynamic range, 50 to 600 A in one package.
Accuracy - Dynamic performance data
X
L
Accuracy 2) @ IPN, TA = 25C, @ 15 V Linearity 2) Electrical offset voltage @ IP = 0, TA = 25C Residual offset voltage @ IP = 0 after an overload of 3 x IPN Thermal drift of offset voltage TA = - 25 .. + 85C Thermal drift of gain TA = - 25 .. + 85C Response time @ 90 % of IP di/dt accurately followed Frequency bandwidth (- 3 dB) 3)
VOE VOM VOT TCG tr di/dt f
1 0.5 Max 10 10 1 0.05 <3 > 50 DC .. 50
% % mV mV mV/K %/K s A/s kHz
Applications
* AC variable speed drives and servo
motor drives
General data
TA TS m Ambient operating temperature Ambient storage temperature Mass Standards Safety EMC Deviation in output when tested to EN 61000-4-6 Deviation in output when tested to EN 61000-4-4 - 25 .. + 85 C - 25 .. + 85 C 75 g EN50178 (1994) EN50082-2 (1992) EN50081-1 (1992) < 10 % of IPN < 10 % of IPN
* Static converters for DC motor drives * Battery supplied applications * Uninterruptable Power Supplies
(UPS)
* Switched Mode Power Supplies
(SMPS)
* Power supplies for welding
applications.
Notes :
1) 2) 3)
Reinforced insulation, Overvoltage Category II, Pollution Degree 2 Excludes the electrical offset Refer to derating curves in the technical file to avoid excessive core heating at high frequency 001114/2
LEM Components
www.lem.com
Dimensions HAL 200-S (in mm. 1 mm = 0.0394 inch)
Bottom view Left view
Secondary terminals
Terminal Terminal Terminal Terminal 1 2 3 4 : supply voltage + 15 V : supply voltage - 15 V : output : 0V
Front view Mechanical characteristics
* General tolerance * Primary through-hole * Connection of secondary
0.5 mm 20 mm x 15 mm Molex 5045-04-A
Remarks
* VOUT is positive when IP flows in the direction of the arrow. * Temperature of the primary conductor should not exceed
90C.
* This is a standard model. For different versions (supply
voltages, secondary connections, unidirectional measurements, operating temperatures, etc.) please contact us.
LEM have a policy of continual product improvement and the company reserves the right to revise the above specification without prior notice.


▲Up To Search▲   

 
Price & Availability of HAL200-S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X