Monitoring Relays AC Current Transformer Type E 82-20 * 3 input ranges in one unit: 0 - 5 AAC 0 - 10 AAC 0 - 25 AAC or 0 - 20 AAC 0 - 30 AAC 0 - 50 AAC * Output 4-20 mADC * Easy interface to PLC or setpoint relays * For mounting on DIN-rail in accordance with DIN/EN 50 022 * 22.5 mm small Euronorm housing Product Description Small AC current metering transformer with 3 knob selectable ranges. Output from the transformer is 4-20 mADC in accordance with IEC 60381-1. Can be used with relays DIB01, PIB01, DIC01, PIC01 or S183 or directly connected to a PLC. Power supply ON is indicated by a green LED. 12 mm hole for isolated current carrying wire makes it suitable for most applications. For mounting on DIN-rail or directly on surface by screws. Ordering Key Type Output Input current (highest range) E 82-20 50 Type Selection Input current 0- 5 AAC 0-10 AAC 0-25 AAC 0-20 AAC 0-30 AAC 0-50 AAC Output current 4 - 20 mA 4 - 20 mA 4 - 20 mA 4 - 20 mA 4 - 20 mA 4 - 20 mA Switch position 5 10 25 20 30 50 Type no. E82-20 25 E82-20 25 E82-20 25 E82-20 50 E82-20 50 E82-20 50 Input Specifications Current range Max. current (continuously) Max. overload current (t = 30 s) Overvoltage category Frequency range 0 - 5 AAC 50 AAC 150 AAC III (IEC 60664) 40 Hz - 1 kHz 0 - 10 AAC 50 AAC 150 AAC III (IEC 60664) 40 Hz - 1 kHz 0 - 20 AAC 100 AAC 300 AAC III (IEC 60664) 40 Hz - 1 kHz 0 - 25 AAC 50 AAC 150 AAC III (IEC 60664) 40 Hz - 1 kHz 0 - 30 AAC 100 AAC 300 AAC III (IEC 60664) 40 Hz - 1 kHz 0 - 50 AAC 100 AAC 300 AAC III (IEC 60664) 40 Hz - 1 kHz Output Specifications Output current (sink) Maximum output current Tolerance of output current @ 50 Hz Temperature variation Frequency variation Power supply (loop voltage) 4-20 mADC 35 mADC 2% 400 ppm/C 10 ppm/Hz 10-40 VDC General Specifications (cont.) Environment Degree of protection Pollution degree Operating temperature Housing Dimensions Material Weight Approval CE Marking EMC Immunity IP 20 3 -20 to +50C (-4 to +122F) 22.5 x 56 x 49 mm ABS 70 g UL Yes Electromagnetic Compatibility Acc. to EN 61000-6-1 (tolerance of output current: 2%) Acc. to EN 61000-6-2 (tolerance of output current: 5%) Acc. to EN 61000-6-3 General Specifications Power ON delay Reaction time <1s < 100 ms worst case reaction time may be up to 5 x LED, green Indication for Power supply ON Emission Specifications are subject to change without notice (15.09.06) 1 E 82-20 Mode of Operation The E 82-20 is a small AC current metering transformer with standardized 4-20 mADC output. This makes it very useful as an AC current interface to a PLC with 4-20 mADC input. Used with relays DIB01, PIB01, DIC01, PIC01 or S 183, one or more setpoints can monitor the current and signal alarm. S 183 also provides the DC voltage supply for the E 82-20. In the 5 A range the E 82-20 is often used as a 4-20 mADC signal converter for larger standard AC current transformers with 5 AAC secondary output. The metered conductor is drawn through the central hole of the current metering transformer. It is possible to measure currents below the nominal range by drawing the conductor through the hole several times. If the conductor is drawn through the central hole e.g. 5 times, the transformer will register 5 AAC when the current in the conductor is 1 AAC. Input/Output Curve Output (mADC) Resistance/Voltage Curve Max. R load () 20 16 12 8 4 50 100 Input (% of range) (V) Loop voltage Max. load resistance versus loop voltage Wiring Diagram Dimensions 1 I ~ I 2 R load 55.4 22.5 47.4 15 56 O 12 o12 49 4 x o3.4 20 2 Specifications are subject to change without notice (15.09.06) |
Price & Availability of E82-2050
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |