  Datasheet File OCR Text:
 Filename: TFS110T.doc
Version 2.3
13.03.2002
VI TELEFILTER
Filter specification
TFS 110 T
1/5
Measurement condition
Ambient temperature: 23 C Input power level : 0 dBm Terminating impedances at fc *: for input: for output:
930 || - 13,5 pF 940 || - 15,2 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 110 T is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 110.592 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
Insertion loss (reference level) Nominal frequency Centre frequency Relative attenuation arel fN fN 0,6 ... fN MHz ... fN 0,3 5 MHz MHz
ae = amin
typ. value
7,5 dB
tolerance / limit
max. 14,0 dB
fN
fc
-
110,592 MHz
110,592 MHz
38 380 dB ns
2
max. min.
3 30
dB dB nsec
Group delay ripple in PB Temperature coefficient Operating temperature range Storage temperature range Input power
max. 800
0,032 ppm/K
- 40 C ... + 85 - 40 C ... + 85 max. 10
C C dBm
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
Generated:
Checked / approved: Construction and Pin Connection
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Filename: TFS110T.doc
Version 2.3
13.03.2002
VI TELEFILTER
(All dimensions in mm)
Filter specification
TFS 110 T
2/5
6,50 - 0,10
+ 0,20
TFS 110T
P02
19 - 0,10
2,0 Max.
12
+ 0,20
Date code
1 2 3 4 5 6 7 8 9 10
Input RF Return Ground Ground Ground Output Output RF Return Ground Ground Ground Input
1
1,02
Date code: M N P ...
Year+week 2000 2001 2002
1,91 7,62
50 test circut
L1 10 Input 50 Ohm C1 5 L2 Output 50 Ohm C2
1,2,3,4,6,7,8,9
Stability characteristics
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
2,31
SAW
Filename: TFS110T.doc
Version 2.3
13.03.2002
VI TELEFILTER
Filter specification
TFS 110 T
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N
4. Resistance to solder heat (reflow):
reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 2000 min 300 mm min 500 mm min 300 mm
T a p e (a ll d im e n s io n s in m m ) W Po Do E S0 P2 P1 Ao Bo Ko t Ct : : : : : : : : : : : : 32 4 1 ,5 0 ,3 0 ,1 + 0 ,5
1 ,7 5 0 ,1 2 8 ,4 0 ,1 2 12 1 ,5 7 ,1 1 9 .6 2 ,0 0 ,3 5 2 5 ,5 0 ,1 0 ,1 0 ,1 0 ,0 5 0 ,1 0 ,1 0 ,1
pull off direction
X-X
t Do Po P1 P2 E
X
So
D 1 (m in ) :
Ko
view direction
Ao
C t
D1
Bo
W
X
W2
SPEC-Gurt 0061/ 19X6,5 Q09016:02.001 Jul.10,01
Reel (all dimensions in mm): A : 330 32,4 +2 38,4 100 13 +0,5/-0,2
A
W1 : W2 (max) : N (min) C : :
C
N
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Filename: TFS110T.doc
Version 2.3
13.03.2002
VI TELEFILTER
Filter specification
TFS 110 T
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
History
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Filename: TFS110T.doc
Version 2.3
13.03.2002
VI TELEFILTER
Filter specification
TFS 110 T
5/5
Version 1.0 1.1 1.2 1.3
Reason of Changes - identical with specification from hudson - history added - Change package to 15mm x 6mm - use harder conditions for "Stability characteristics" - change to centre frequency reference for attenuation - add additional attenuation requirements
Name Sabah Steiner Herrler Steiner
Date 06.01.2000 13.07.2000 17.08.2001 29.08.2001
development specification
2.0 changes requested by customer introduced wider passband 10dB/20dB attenuation demands removed temperature range corrected according to TFS110B specification change 30 dB edge frequencies - changed values of rejection, group delay, operating temperature - changed package - terminating impedance added - typical values added - limit of max. input power added Steiner 23.11.2001
2.1 2.2 2.3
Pfeiffer Pfeiffer Pfeiffer
10.01.2002 12.03.2002 13.03.2002
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information