APT4012BVFR APT4012SVFR 400V 37A BVFR 0.120 D3PAK POWER MOS V (R) FREDFET TO-247 Power MOS V(R) is a new generation of high voltage N-Channel enhancement mode power MOSFETs. This new technology minimizes the JFET effect, increases packing density and reduces the on-resistance. Power MOS V(R) also achieves faster switching speeds through optimized gate layout. SVFR * Faster Switching * Lower Leakage * Fast Recovery Body Diode MAXIMUM RATINGS Symbol VDSS ID IDM VGS VGSM PD TJ,TSTG TL IAR EAR EAS Parameter Drain-Source Voltage * Avalanche Energy Rated * TO-247 or Surface Mount D3Pak G D S All Ratings: TC = 25C unless otherwise specified. APT4012BVFR_SVFR UNIT Volts Amps 400 37 148 30 40 370 2.96 -55 to 150 300 37 30 4 1 Continuous Drain Current @ TC = 25C Pulsed Drain Current Gate-Source Voltage Continuous Gate-Source Voltage Transient Total Power Dissipation @ TC = 25C Linear Derating Factor Operating and Storage Junction Temperature Range Lead Temperature: 0.063" from Case for 10 Sec. Avalanche Current 1 Volts Watts W/C C Amps mJ (Repetitive and Non-Repetitive) 1 Repetitive Avalanche Energy Single Pulse Avalanche Energy 1300 STATIC ELECTRICAL CHARACTERISTICS Symbol BVDSS ID(on) RDS(on) IDSS IGSS VGS(th) Characteristic / Test Conditions Drain-Source Breakdown Voltage (VGS = 0V, ID = 250A) On State Drain Current 2 MIN TYP MAX UNIT Volts Amps 400 37 0.12 250 1000 2 4 100 (VDS > ID(on) x R DS(on) Max, VGS = 10V) 2 Drain-Source On-State Resistance (VGS = 10V, 0.5 ID[Cont.]) Ohms A 1-2006 050-7271 Rev B Zero Gate Voltage Drain Current (VDS = VDSS, VGS = 0V) Zero Gate Voltage Drain Current (VDS = 0.8 VDSS, VGS = 0V, TC = 125C) Gate-Source Leakage Current (VGS = 30V, VDS = 0V) Gate Threshold Voltage (VDS = VGS, ID = 1.0mA) APT Website - http://www.advancedpower.com nA Volts CAUTION: These Devices are Sensitive to Electrostatic Discharge. Proper Handling Procedures Should Be Followed. DYNAMIC CHARACTERISTICS Symbol Ciss Coss Crss Qg Qgs Qgd t d(on) tr t d(off) tf Characteristic Input Capacitance Output Capacitance Reverse Transfer Capacitance Total Gate Charge 3 APT4012BVFR_SVFR Test Conditions VGS = 0V VDS = 25V f = 1 MHz VGS = 10V VDD = 200V ID = 37A @ 25C VGS = 15V VDD = 200V ID = 37A @ 25C RG = 1.6 MIN TYP MAX UNIT pF 4500 690 290 195 25 90 14 17 55 12 ns nC Gate-Source Charge Gate-Drain ("Miller") Charge Turn-on Delay Time Rise Time Turn-off Delay Time Fall Time SOURCE-DRAIN DIODE RATINGS AND CHARACTERISTICS Symbol IS ISM VSD dv/ dt Characteristic / Test Conditions Continuous Source Current (Body Diode) Pulsed Source Current Diode Forward Voltage 1 2 MIN TYP MAX UNIT Amps Volts V/ns ns 37 148 1.3 15 Tj = 25C Tj = 125C Tj = 25C Tj = 125C Tj = 25C Tj = 125C (Body Diode) (VGS = 0V, IS = -37A) 5 Peak Diode Recovery dv/dt Reverse Recovery Time (IS = -37A, di/dt = 100A/s) Reverse Recovery Charge (IS = -37A, di/dt = 100A/s) Peak Recovery Current (IS = -37A, di/dt = 100A/s) t rr Q rr IRRM 250 525 1.6 6.0 13 21 C Amps THERMAL CHARACTERISTICS Symbol RJC RJA Characteristic Junction to Case Junction to Ambient MIN TYP MAX UNIT C/W 0.34 40 1 Repetitive Rating: Pulse width limited by maximum junction temperature. 2 Pulse Test: Pulse width < 380 s, Duty Cycle < 2% 3 See MIL-STD-750 Method 3471 4 Starting T = +25C, L = 1.90mH, R = 25, Peak I = 37A j G L 5 dv/ numbers reflect the limitations of the test circuit rather than the dt device itself. IS -ID Cont. di/dt 700A/s VR VDSS TJ 150C [ ] APT Reserves the right to change, without notice, the specifications and information contained herein. 0.4 , THERMAL IMPEDANCE (C/W) D=0.5 0.1 0.05 0.2 0.1 0.05 PDM 1-2006 0.01 0.005 0.02 0.01 Note: t1 t2 050-7271 Rev B JC Z SINGLE PULSE 0.001 10-5 Duty Factor D = t1/t2 Peak TJ = PDM x ZJC + TC 10-3 10-2 10-1 1.0 10 RECTANGULAR PULSE DURATION (SECONDS) FIGURE 1, MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs PULSE DURATION 10-4 Typical Performance Curves 100 7V ID, DRAIN CURRENT (AMPERES) ID, DRAIN CURRENT (AMPERES) APT4012BVFR_SVFR 100 VGS=15V 80 VGS=10V 6.5V 60 7V VGS=10V & 15V 80 6.5V 60 6V 6V 40 5.5V 5V 40 5.5V 5V 20 4.5V 0 40 80 120 160 200 VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS) FIGURE 2, TYPICAL OUTPUT CHARACTERISTICS 0 20 4.5V 0 4 8 12 16 20 VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS) FIGURE 3, TYPICAL OUTPUT CHARACTERISTICS 0 RDS(ON), DRAIN-TO-SOURCE ON RESISTANCE 100 ID, DRAIN CURRENT (AMPERES) TJ = -55C TJ = +25C TJ = +125C 1.5 V GS NORMALIZED TO = 10V @ 0.5 I [Cont.] D 80 1.4 1.3 1.2 60 VDS> ID (ON) x RDS (ON)MAX. 250SEC. PULSE TEST @ <0.5 % DUTY CYCLE VGS=10V VGS=20V 40 1.1 1.0 0.9 20 TJ = +125C 0 TJ = +25C TJ = -55C 0 2 4 6 8 VGS, GATE-TO-SOURCE VOLTAGE (VOLTS) FIGURE 4, TYPICAL TRANSFER CHARACTERISTICS 40 ID, DRAIN CURRENT (AMPERES) 0 20 40 60 80 100 ID, DRAIN CURRENT (AMPERES) FIGURE 5, RDS(ON) vs DRAIN CURRENT BVDSS, DRAIN-TO-SOURCE BREAKDOWN VOLTAGE (NORMALIZED) 1.15 1.10 30 1.05 20 1.00 10 0.95 50 75 100 125 150 TC, CASE TEMPERATURE (C) FIGURE 6, MAXIMUM DRAIN CURRENT vs CASE TEMPERATURE RDS(ON), DRAIN-TO-SOURCE ON RESISTANCE (NORMALIZED) 0 25 -25 0 25 50 75 100 125 150 TJ, JUNCTION TEMPERATURE (C) FIGURE 7, BREAKDOWN VOLTAGE vs TEMPERATURE 1.2 0.90 -50 2.5 I = 0.5 I [Cont.] D D VGS(TH), THRESHOLD VOLTAGE (NORMALIZED) V GS = 10V 2.0 1.1 1.0 0.9 0.8 0.7 1.5 1.0 0.5 0.0 -50 -25 0 25 50 75 100 125 150 TJ, JUNCTION TEMPERATURE (C) FIGURE 8, ON-RESISTANCE vs. TEMPERATURE -25 0 25 50 75 100 125 150 TC, CASE TEMPERATURE (C) FIGURE 9, THRESHOLD VOLTAGE vs TEMPERATURE 0.6 -50 050-7271 Rev B 1-2006 APT4012BVFR_SVFR 200 100 ID, DRAIN CURRENT (AMPERES) OPERATION HERE LIMITED BY RDS (ON) 10S 100S C, CAPACITANCE (pF) 15,000 10,000 5,000 Ciss 50 1mS 10 5 10mS 100mS DC Coss 1,000 Crss 500 1 .5 TC =+25C TJ =+150C SINGLE PULSE .1 1 5 10 50 100 400 VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS) FIGURE 10, MAXIMUM SAFE OPERATING AREA I = I [Cont.] D D .01 .1 1 10 50 VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS) FIGURE 11, TYPICAL CAPACITANCE vs DRAIN-TO-SOURCE VOLTAGE IDR, REVERSE DRAIN CURRENT (AMPERES) 100 VGS, GATE-TO-SOURCE VOLTAGE (VOLTS) 20 100 50 TJ =+150C TJ =+25C 16 VDS=80V VDS=200V 12 VDS=320V 8 10 5 4 50 100 150 200 250 300 350 Qg, TOTAL GATE CHARGE (nC) FIGURE 12, GATE CHARGES vs GATE-TO-SOURCE VOLTAGE 0 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 VSD, SOURCE-TO-DRAIN VOLTAGE (VOLTS) FIGURE 13, TYPICAL SOURCE-DRAIN DIODE FORWARD VOLTAGE 1 TO-247 (BVFR) Package Outline Drain (Heat Sink) 4.69 (.185) 5.31 (.209) 1.49 (.059) 2.49 (.098) 6.15 (.242) BSC D PAK (SVFR) Package Outline 4.98 (.196) 5.08 (.200) 1.47 (.058) 1.57 (.062) 15.95 (.628) 16.05 (.632) 13.41 (.528) 13.51 (.532) 3 15.49 (.610) 16.26 (.640) 5.38 (.212) 6.20 (.244) 1.04 (.041) 1.15 (.045) Drain 20.80 (.819) 21.46 (.845) 3.50 (.138) 3.81 (.150) Revised 4/18/95 13.79 (.543) 13.99 (.551) Revised 8/29/97 11.51 (.453) 11.61 (.457) 0.46 (.018) 0.56 (.022) {3 Plcs} 4.50 (.177) Max. 2.87 (.113) 3.12 (.123) 1.65 (.065) 2.13 (.084) 1.01 (.040) 1.40 (.055) 1-2006 0.40 (.016) 0.79 (.031) 0.020 (.001) 0.178 (.007) 2.67 (.105) 2.84 (.112) 1.27 (.050) 1.40 (.055) 1.98 (.078) 2.08 (.082) 5.45 (.215) BSC {2 Plcs.} 19.81 (.780) 20.32 (.800) 1.22 (.048) 1.32 (.052) 3.81 (.150) 4.06 (.160) (Base of Lead) 050-7271 Rev B Gate Drain Source Heat Sink (Drain) and Leads are Plated 2.21 (.087) 2.59 (.102) 5.45 (.215) BSC 2-Plcs. Dimensions in Millimeters and (Inches) Source Drain Gate Dimensions in Millimeters (Inches) APT's products are covered by one or more of U.S.patents 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522 5,262,336 6,503,786 5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058 and foreign patents. US and Foreign patents pending. All Rights Reserved. |
Price & Availability of APT4012BVFR
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |