 Current Transducer HTFS 200..800-P/SP2
For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 200 - 400 - 800A
All Data are given with a R L = 10 k
Electrical data
Primary nominal r.m.s. current IPN (A)
200 400 800
Primary current measuring range IP (A)
300 600 1200
Type
Features
* Hall effect measuring principle * Galvanic isolation between primary * Low power consumption * Single power supply +5V * Ratiometric offset * TA = -40..+105 C * PCB fixation by 4 O1 pins
and secondary circuit
HTFS 200-P/SP2 HTFS 400-P/SP2 HTFS 800-P/SP2
VOUT VREF
RL ROUT CL VC IC
Analog output voltage @ IP IP = 0 Internal Reference1) - Output voltage VREF Output impedance VREF Load impedance Output load resistance Output impedance Max. output capacitive load Supply voltage ( 5 %) Current consumption @ VC = 5 V
VREF (1.25*IP/IPN) V VREF 0.025 V 1/2VC 0.025 V typ. 200 200 k 2 k < 10 <1 F 5 V 22 mA
Advantages
* Small size and space saving * Only one design for wide current * High immunity to external
ratings range interference.
Accuracy - Dynamic performance data
Accuracy @ IPN , TA = 25C Linearity 0 .. 1.5 x IPN TCVOUT Thermal drift of VOUT @ IP = 0 TCVREF Thermal drift of VREF TCVOUT / VREF Thermal drift of VOUT / VREF @ IP = 0 TCG Thermal drift of the gain VOM Residual voltage @ IP = 0, after an overload of 3 x IPN DC t ra Reaction time @ 10 % of IPN tr Response time @ 90 % of IPN di/dt di/dt accurately followed Output noise (DC ..10 kHz) (DC .. 1 MHz) f Frequency bandwidth (-3 dB) 3)
L
X
2)
1 0.5 0.3 0.01 0.2 <0.5 <3 <7 > 100 < 15 < 40 DC .. 20
% of IPN % of IPN mV/K %/K mV/K % of IPN s s A/s mVpp mVpp kHz
* VREF. IN/OUT
Applications
* Forklift drives * AC variable speed drives * Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies * Switched Mode Power Supplies * Power supplies for welding
applications. (SMPS) (UPS)
0.05% of reading/K
General data
TA TS dCp dCl CTI m Ambient operating temperature Ambient storage temperature Creepage distance Clearance distance Comparative tracking index (Group IIIa) UL94 classification Mass Standards - 40 .. + 105 - 40 .. + 105 >4 >4 220 V0 60 C C mm mm V g 041222/2
EN 50178 (97-10-01)
LEM Components
w w w .lem.com
Current Transducer HTFS 200..800-P/SP2
Insulation category
Vb Nominal Voltage with IEC 61010-1 standards and following conditions - Single insulation - Over voltage category III - Pollution degree 2 - Heterogeneous field Nominal Voltage with EN 50178 standards and following conditions - Reinforced insulation - Over voltage category III - Pollution degree 2 - Heterogeneous field R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn R.m.s. voltage for partial discharge extinction @ 10pC Impulse withstand voltage 1.2/50s 150 V r.m.s.
Vb
150
V r.m.s.
Vd Ve Vw
2.5 >1 4
kV kV kV
If insulated cable is used for the primary circuit, the voltage category could be improved with the following table : Cable insulation (primary) Category HAR 03 300V CAT III HAR 05 400V CAT III HAR 07 500V CAT III
Notes : 1) It is possible to overdrive VREF with an external reference voltage between 2 - 2.8 V providing its ability to sink or source approx. 2.5 mA. 2) Excluding offset. 3) Small signal only to avoid excessive heatings of the magnetic core.
Safety :
Caution, risk of danger
Caution, risk of electrical shock
This transducer shall be used in accordance with manufacturer instruction. Power supply shall be a low voltage source and shall have an efficient protective system against over current. Power supply must incorporate a circuit breaker. This transducer shall be used in an electric/electronic equipment in respect of standards rules and applicable safety requirements. Primary bar and output terminals can provide hazardous voltage. This transducer is a built in device, of which conducting parts must be inaccessible by installation. Protective envelope or additional shield must be used.
w w w .lem.com
LEM Components
HTFS 200..800-P/SP2 Dimensions (in mm)
Ip
0.5 33 16.5 R3 3 40
33
d22 16 5 26 3-P=2.54
4
4-d=1.0
1
4-0.25x0.5
3.5+/-1
4.5 7
Required Connection Circuit
Terminal Pin
HTFS 4
Ref-IN
Vref(IN/OUT) Output
47nF 47nF 4.7nF
3 Output 2 0V 1
+5V
1...+5V 2...0V 3...Output 4...Vref(IN/OUT)
0V +5V
Operation Principle
+Vc Vout Vref.(IN/OUT) Ip 0V
Mechanical characteristics
* * * * General tolerance Fixation Recommended PCB hole Fastening & connection of secondary Recommended PCB hole 0.2 mm 4 pins x O 1.0 O 1.2 mm 4 pins 0.5 x 0.25 O 0.7 mm
Remarks
* VOUT is positive when IP flows in the direction of the arrow. * Temperature of the primary conductor should not exceed 120C.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
20.3


▲Up To Search▲   

 
Price & Availability of HTFS800-P

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X