 NLP110 Medical Series
Single and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES * * * * * * * * * 80-110W AC/DC Universal Input Switch Mode Power Supplies 1 Provides low voltage outputs Compliance to EN61000-3-2 (Power Factor = 0.98) Smallest industry standard package 6.5 x 3.0 x 1.26 inches 90VAC to 264VAC universal input range UL, cUL, and VDE safety approvals and CE-Marked to MDD Overvoltage and short circuit protection VDE0871-A, EN55022-A, EN55011-A conducted noise VDE0871-A, EN55022-A, EN55011-A radiated noise Meets all applicable and relevant immunity standards EN61000-4-2,4,5 and 6
The NLP110 Medical is a series of 110W AC/DC open-frame power supplies in a 3" x 6.5" x 1.26" package. The NLP110 Medical is power factor corrected to meet EN61000-3-2 and is available in single and multiple output models. The multiple output models have a capability that is unique to the power supply market - they can deliver equal amounts of current on multiple low voltage outputs to support designs that will span the industry transition from 5V logic to 3.3V logic. The NLP110 Medical is practically the same size as a 65 Watt 3" x 5" product, e.g. NLP65 Medical - the one difference is that the footprint is a mere 1.5 inches longer. The NLP110 Medical series, with full medical safety approval per UL2601-1, C22.2 No. 601.1-M90, VDE0750, IEC60601-1 and EN60601-1 and CE marked, greatly accelerating design-in time and reducing system compliance costs.
All specifications are typical at nominal input, full load at 25C unless otherwise stated
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS Total regulation (Line and load) Rise time Transient response Main output Auxiliary outputs At turn-on Main output 75% to 100% step at 0.1A/s 2.0% 5.0% 1.0s, max. 5.0% or 250mV max. dev., 1ms max. recovery to 1% 0.02%/C Main outputs Cyclic operation Single and multiple 125%, 10% Continuous See table
EMC CHARACTERISTICS (continued) Surge Fast transients Radiated immunity Conducted immunity EN61000-4-5 EN61000-4-4 EN61000-4-3 EN61000-4-6 Level Level Level Level 3 3 3 3
GENERAL SPECIFICATIONS Hold-up time Efficiency Isolation voltage Approvals and standards Weight 120VAC, 60Hz 120VAC, 80W (-9605) Input/output Input/chassis 16.7ms @ 110W 75% min. 4000VAC 1500VAC
Temperature coefficient Overvoltage protection Short circuit protection Minimum output current INPUT SPECIFICATIONS Input voltage range (See Note 6) Input frequency range Input surge current (cold start) Safety ground leakage current Input current 120VAC 230VAC 230VAC, 50Hz 120VAC 120VAC 230VAC 230VAC @ @ @ @ 80W 110W 80W 110W Universal input
EN60601-1, IEC60601-1,VDE0750, UL2601-1, C22.2 No. 601.1-M90 283g (10oz) MIL-HDBK-217F
(9)
90 to 264VAC 47Hz to 63Hz 18A max. 35A max. <100A 0.9A 1.3A 0.48A 0.7A rms rms rms rms
MTBF (@ 25C)
220,000 hours min.
ENVIRONMENTAL SPECIFICATIONS Thermal performance
Operating ambient, 0C to +50C (See derating curve) Non-operating -40C to +85C 50C to 70C, ambient, Derate to convection cooled 50% load 0C to 50C, ambient, 80W convection cooled 0C to 50C ambient, 110W 150LFM forced air Peak (0C to +50C, 60s) (See Note 3) Non-condensing Operating Non-operating 5Hz to 500Hz per MIL-STD-810E 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4G rms peak 516.4 Part IV
Input fuse
UL/IEC127
(12)
F3.15A H, 250VAC
Relative humidity Altitude
EMC CHARACTERISTICS Conducted emissions Radiated emissions Harmonic current emission correction ESD air ESD contact
EN55022, FCC part 15 EN55022, FCC part 15 EN61000-3-2 EN61000-4-2 EN61000-4-2
Level A Level A Compliant Level 3 Level 3
Vibration (See Note 8) Shock
File Name: NLP110M.PDF Rev: 13 Dec 2002
NLP110 Medical Series
Single and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies 2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT PEAK MIN
(6) (4)
OUTPUT VOLTAGE +5V +12V +48V +24V +5V (A) +3.3V (B) +12V +3.3V (A) +2.5V (B) +12V +12V (A) +3.3V (B) -12V +12V (A) +5V (B) -12V Notes
1
RIPPLE 50mV
(5)
TOTAL REGULATION
MODEL NUMBERS NLP110-9905 NLP110-9912 NLP110-9917 NLP110-9924 NLP110-9993
MAX
(1)
150LFM 22A 9.2A 2.3A 4.6A 16A 16A 1.0A 16A 16A 1.0A 8.5A 16A 1.0A 8.5A 16A 1.0A
(2)
300LFM 22A 9.2A 2.3A 4.6A 18A 20A 1A 20A 20A 1A 8.5A 20A 1A 8.5A 18A 1A
(3)
0.5A 0.3A 0A 0.2A 0.5A 0.2A 0A 0.5A 0.1A 0A 0.2A 0.5A 0A 0.2A 0.2A 0A
15A 6.4A 1.6A 3.2A 13A 13A 0.65A 13A 13A 0.65A 6.5A 13A 0.65A 6.5A 13A 0.65A
22A 11.5A 2.5A 6.0A 18A 20A 1.0A 22A 22A 1.0A 10A 22A 1.0A 10A 22A 1.0A N
6
2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 5.0% 2.0% 2.0% 5.0% 2.0% 2.0% 5.0% 2.0% 2.0% 5.0%
120mV 240mV 240mV 50mV 50mV 120mV 50mV 50mV 120mV 1200mV 50mV 120mV 120mV 50mV 120mV
NLP110-9994
NLP110-9995
(7)
NLP110-9908
(7)
2
3
4 5
Free air convection. Multiple output units: maximum continuous output power not to exceed 80W. For -9993; I3.3V = 13A max.; I5.0V = 13A max.; I3.3V + I5.0V 16A. For -9994; I3.3V = 13A max.; I2.5V = 13A max.; I3.3V + I2.5V 16A For -9995; I3.3V = 13A max.; I12V = 6.5A max.; I3.3V + I12V 16A. For -9908; I5.0V = 13A max.; I12V = 6.5A max.; I5.0V + I12V 16A. Single output units: maximum continuous output power not to exceed; 75W on -9905; 76.8W on -9912,-9924, and -9917. 150LFM forced air cooling from L4 side. Multiple output units: maximum continuous output power not to exceed 105W. For -9993; I3.3V = 16A max.; I5.0V = 16A max.; I3.3V + I5.0V 20A. For -9994; I3.3V = 16A max.; I2.5V = 16A max.; I3.3V + I2.5V 20A For -9995; I3.3V = 16A max.; I12V = 8.5A max.; I3.3V + I12V 20A. For -9908; I5.0V = 16A max.; I12V = 8.5A max.; I5.0V + I12V 20A. Single output units: maximum continuous output power not to exceed 110W for all models. 300LFM forced air cooling from L4 side. Multiple output units: maximum continuous output power not to exceed 110W. For -9993; I3.3V = 20A max.; I5.0V = 18A max.; I3.3V + I5.0V 22A. For -9994; I3.3V = 20A max.; I2.5V = 20A max.; I3.3V + I2.5V 22A For -9995; I3.3V = 20A max.; I12V = 8.5A max.; I3.3V + I12V 22A. For -9908; I5.0V = 20A max.; I12V = 8.5A max.; I5.0V + I12V 22A. Single output units: maximum continuous output power not to exceed 110W for all models. Peak output current lasting less than 30 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation limits. Figure is peak-to-peak for convection power rating. Output noise measurements are made across a 20MHz bandwidth using a 6" twisted pair, terminated with a 10F electrolytic capacitor and a 0.1F ceramic capacitor.
7 8 9 10 11 12
13
Minimum load required for correct start-up and operation on single outputs and on main output of multiple versions. Failure to observe minimum load on main output will not allow the supply to start-up correctly. Some electronic test loads have a large delay time before they start drawing current even though the voltage from the supply is present. During this time delay, there is no load on the output and as a result, the supply cannot start-up properly and maintain its correct output voltage. In these instances, a dummy resistive load across the output may be necessary to load the output of the supply until the test load can function correctly and draw the intended minimum load. Minimum load required on auxiliary outputs to maintain regulation. For models NLP110-9908 and NLP110-9995, the 12V output is floating. For -12V output, pin 11 on J2 has to be connected to Return making pin 12 the -12V output Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G rms 5Hz to 500Hz. For optimum reliability, no part of the heatsink should exceed 110oC, and no semiconductor case temperature should exceed 120oC. CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. The EMI specifications reference measurements made with the power supply mounted on a grounded metal sheet extending 1 inch beyond each edge, using an unshielded cable. No external filtering required during conducted emissions testing but some applications may require additional filtering to achieve system compliance. A line choke, (AC input cords looped twice through an EMI suppression toroid) was used during radiated emissions testing. Considerable radiated testing in 1U six-sided boxes has shown that units can meet level B in typical systems. Application support is available from the factory to assist with EMI compliance. All models require a minimum mounting stand-off of 6.35mm (0.25 inches) in the end use product.
International Safety Standard Approvals
VDE0750/IEC60601-1 and EN60601-1 UL2601-1 and C22.2 No. 601.1-M90.
www.artesyn.com
File Name: NLP110M.PDF Rev: 13 Dec 2002
NLP110 Medical Series
Single and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies 3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Mechanical Notes
A All dimensions are in inches (mm).
2
6.50 (165.10) 6.050 (153.670) 0.23 (5.842) 12
4
3
J4
1
J2
!
2.550 (64.770) 3.00 (76.20)
F1
1 3
T1 (REF.)
J1
J3
J5
ALL DIMENSIONS IN INCHES (mm) MAXIMUM COMPONENT HEIGHT IS 1.26 (32.00)
1 1 2
2 1
Recommended direction for forced air relative to power supply orientation shown below.
1 2 3 4 Optimum. Very good. Good. Not recommended.
0.23 (5.842)
INPUT PIN CONNECTIONS J1 Pin 1 AC Neutral Pin 2 No Connection Pin 3 AC Line J3 Pin 1 V (A) Sense + Pin 2 V (A) Sense J4 Pin 1 Safety Earth J5 Pin 1 V (B) Sense + Pin 2 V (B) Sense Input and output connectors
AC (J1) connector type Molex 26-60-4030 or equivalent.
J2 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12
OUTPUT PIN CONNECTIONS SINGLE TRIPLE No Connection V (B) No Connection V (B) No Connection V (B) Return Return Return Return Return Return Return Return V (A) V (A) V (A) V (A) V (A) V (A) No Connection V (C) No Connection V (C) Return
DERATING CURVE
Output Power (Watts)
110W 80W
150 LFM FORCED AIR COOLING
NATURAL CONVECTION COOLING
55W 40W
0C 10C20C30C40C50C60C 70C
(7)
Mating connectors
AC (J1) mating connector type Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals. DC (J2) mating connector type Molex Spox type 26-03-3121 and contact 08-52-0113. Sense (J3) mating connector type Molex 22-01-3027 and contact 08-50-0113. Earth (J4) mating connector type Molex 90028. Sense (J5) mating connector type Leoco 2420S020000 and contact 2453TPB00V1.
DC (J2) connector type 12 position Molex Spox type 26-48-1125 or equivalent. Sense (J3) connector type Molex 22-23-2021 or equivalent. Earth (J4) connector type Male 0.250 quick disconnect. Sense (J5) connector type Leoco 2421P02H000.
Data Sheet (c) Artesyn Technologies(R) 2002 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
www.artesyn.com
File Name: NLP110M.PDF Rev: 13 Dec 2002


▲Up To Search▲   

 
Price & Availability of NLP110-9924

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X