![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TOTAL POWER INT'L 125W Single Output with PFC Function Features : Universal AC input / Full range Built-in active PFC function Protections:Short circuit/Over load/Over voltage PWM control and regulated Built-in remote sense function LED indicator for power on 100% full load burn-in test 125W with 18CFM FAN 5"x3" compact size 3 years warranty High power density 6.117W/inch 3 PPS-125 series SPECIFICATION MODEL DC VOLTAGE RATED CURRENT PPS-125-3.3 3.3V 20A PPS-125-5 5V 20A 0 ~ 20A 0 ~ 25A 100W 125W 100mVp-p 4.75 ~ 5.25V 2.0% 0.5% 1.0% 127 ~ 370VDC PF>0.98/115VAC at full load 80% 80% 80% 83% 83% 83% PPS-125-12 12V 8.5A 0 ~ 8.5A 0 ~ 10.5A 102W 126W 100mVp-p PPS-125-13.5 PPS-125-15 13.5V 7.5A 0 ~ 7.5A 0 ~ 9.3A 101.25W 125.55W 100mVp-p 15V 6.7A 0 ~ 6.7A 0 ~ 8.4A 100.5W 126W 100mVp-p PPS-125-24 24V 4.2A 0 ~ 4.2A 0 ~ 5.2A 100.8W 124.8W 150mVp-p PPS-125-27 27V 3.8A 0 ~ 3.8A 0 ~ 4.6A 102.6W 124.2W 150mVp-p PPS-125-48 48V 2.1A 0 ~ 2.1A 0 ~ 2.6A 100.8W 124.8W 250mVp-p CURRENT RANGE (convection) 0 ~ 20A CURRENT RANGE (18CFM FAN) 0 ~ 25A RATED POWER (convection) 66W OUTPUT RATED POWER (18CFM FAN) 82.5W RIPPLE & NOISE (max.) Note.2 100mVp-p VOLTAGE ADJ. RANGE 3.13 ~ 3.46V VOLTAGE TOLERANCE Note.3 2.0% 11.40 ~ 12.60V 12.82 ~ 14.17V 14.25 ~ 15.75V 22.80 ~ 25.20V 25.65 ~ 28.35V 45.60 ~ 50.40V 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 0.5% 1.0% LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD TIME VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR INPUT EFFICIENCY (Typ.) AC CURRENT 115VAC 230VAC INRUSH CURRENT (max.) 0.5% 1.0% 90 ~ 264VAC 47~63Hz PF>0.93/230VAC 70% 1.2A 0.5% 1.0% 0.5% 1.0% 0.5% 1.0% 0.5% 1.0% 0.5% 1.0% 1000ms, 30ms, 20ms/230VAC 2000ms, 30ms, 20ms/115VAC at full load 79% 1.7A 0.6A 0.75A COLD START 40A/230VAC <2mA / 240VAC 130 ~ 160% rated output power Protection type : Fold back current limiting, recovers automatically after fault condition is removed 3.63 ~ 4.45V 5.5 ~ 6.75V 13.8 ~ 16.2V 15.5 ~ 20.25V 17.25 ~ 20.25V 27.6 ~ 32.4V Protection type : Hiccup mode, recovers automatically after fault condition is removed -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC (Note 4) 31.05 ~ 36.45V 57.6 ~ 67.2V I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A MTBF 111.7Khrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION PACKING 127*76.2*34.6mm (L*W*H) 0.37Kg; 36pcs/13.3Kg/0.89CUFT NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 125W Single Output with PFC Function Mechanical Specification 127 PPS-125 series Unit:mm 115.6 SVR1 LED1 1 CN3 2 1 2 3 CN1 1 2 3 4 5 6 7 8 CN4 4Air flow direction 76.2 64.8 FS1 T2A 250VAC 3. 5 AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/L No Pin AC/N Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent 34.6 DC Output Connector (CN4) : JST B8P-VH or equivalent Pin No. 1~4 5~8 Assignment -V +V Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent (CN3) : Remote Sense Pin No. 1 2 Assignment RSRS+ Derating Curve Output Derating VS Input Voltage 125 100 Forced air 18CFM 100 90 80 70 Free air Convection 70 LOAD (%) 50 LOAD(%) 0 10 20 25 30 40 50 60 70 60 50 40 20 -20 85 100 115 135 155 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz |
Price & Availability of PPS-125
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |