If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Humidity Sensors Humidity Sensor FEATURES * Molded thermoset plastic housing with cover * Linear voltage output vs %RH * Laser trimmed interchangeability * Low power design * High accuracy * Fast response time * Stable, low drift performance * Chemically resistant TYPICAL APPLICATIONS * Refrigeration * Drying * Metrology * Battery-powered systems * OEM assemblies HIH-3610 Series The HIH-3610 Series humidity sensor is designed specifically for high volume OEM (Original Equipment Manufacturer) users. Direct input to a controller or other device is made possible by this sensor's linear voltage output. With a typical current draw of only 200 A, the HIH-3610 Series is ideally suited for low drain, battery operated systems. Tight sensor interchangeability reduces or eliminates OEM production calibration costs. Individual sensor calibration data is available. The HIH-3610 Series delivers instrumentation-quality RH (Relative Humidity) sensing performance in a low cost, solderable SIP (Single In-line Package). Available in two lead spacing configurations, the RH sensor is a laser trimmed thermoset polymer capacitive sensing element with on-chip integrated signal conditioning. The sensing element's multilayer construction provides excellent resistance to application hazards such as wetting, dust, dirt, oils, and common environmental chemicals. WARNING PERSONAL INJURY * DO NOT USE these products as safety or emergency stop devices, or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION * The information presented in this product sheet is for reference only. Do not use this document as system installation information * Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Humidity Sensors Humidity Sensor TABLE 1: PERFORMANCE SPECIFICATIONS Parameter RH Accuracy(1) RH Interchangeability RH Linearity RH Hysteresis RH Repeatability RH Response Time, 1/e RH Stability Power Requirements Voltage Supply Current Supply Voltage Output Vsupply = 5 Vdc Drive Limits Temperature Compensation Effect @ 0% RH Effect @ 100% RH Humidity Range Operating Storage Temperature Range Operating Storage Package(2) Handling HIH-3610 Series Condition 2% RH, 0-100% RH non-condensing, 25 C, Vsupply = 5 Vdc 5% RH, 0-60% RH; 8% @ 90% RH typical 0.5% RH typical 1.2% RH span maximum 0.5% RH 15 sec in slowly moving air at 25 C 1% RH typical at 50% RH in 5 years 4 Vdc to 5.8 Vdc, sensor calibrated at 5 Vdc 200 A at 5 Vdc Vout = Vsupply (0.0062(Sensor RH) + 0.16), typical @ 25 C (Data printout option provides a similar, but sensor specific, equation at 25 C.) 0.8 Vdc to 3.9 Vdc output @ 25 C typical Push/pull symmetric; 50 A typical, 20 A minimum, 100 A maximum Turn-on 0.1 sec True RH = (Sensor RH)/(1.093 -0.0021T), T in F True RH = (Sensor RH)/(1.0546-0.00216T), T in C 0.007 %RH/C (negligible) -0.22% RH/C (<1% RH effect typical in occupied space systems above 15 C (59 F)) 0 to 100% RH, non-condensing (1) 0 to 90% RH, non-condensing -40 C to 85 C (-40 F to 185 F) -51 C to 125 C (-60 F to 257 F) Three pin, solderable SIP in molded thermoset plastic housing with therm oplastic cover Static sensitive diode protected to 15 kV maximum Notes: 1. Extended exposure to 90% RH causes a reversible shift of 3% RH. 2. This sensor is light sensitive. For best results, shield the sensor from bright light. 2 Honeywell * Sensing and Control For application help: call 1-800-537-6945 Humidity/Moisture Sensors Humidity Sensor FACTORY CALIBRATION HIH-3610 sensors may be ordered with a calibration and data printout (Table 2). See order guide on back page. TABLE 2: EXAMPLE DATA PRINTOUT Model Channel Wafer MRP Calculated values at 5 V Vout @ 0% RH Vout @ 75.3% RH Linear output for 2% RH accuracy @ 25 C Zero offset Slope RH Ratiometric response for 0 to 100% RH Vout HIH-3610 Series FIGURE 2: OUTPUT VOLTAGE VS RELATIVE HUMIDITY AT 0 C 4.5 4.0 4.07 Output Voltage (Vdc) HIH-3610-001 92 030996M 337313 0.958 V 3.268 V 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 20 40 60 80 100 Relative Humidity (%) 0.8 Sensor Response Best Linear Fit 0.958 V 30.680 mV/%RH (Vout-zero offset)/slope (Vout-0.958)/0.0307 Vsupply (0.1915 to 0.8130) FIGURE 1: RH SENSOR CONSTRUCTION DIRT, DUST AND OILS DO NOT AFFECT SENSOR FIGURE 3: OUTPUT VOLTAGE VS RELATIVE HUMIDITY AT 0 C, 25 C, 85 C 4.5 4.0 3.5 Output Voltage (Vdc) 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 20 40 60 80 100 Relative Humidity (%) 0.8 4.07 3.90 3.50 THERMOSET POLYMER POROUS PLATINUM LAYER THERMOSET POLYMER PLATINUM LAYER SUBSTRATE (SILICON) For application help: call 1-800-537-6945 Honeywell * Sensing and Control 3 Humidity/Moisture Sensors Humidity Sensor ORDER GUIDE Catalog Listing HIH-3610-001 HIH-3610-002 HIH-3610-003 HIH-3610-004 HIH-3610 Series WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. For application assistance, current specifications, or name of the nearest Authorized Distributor, check the Honeywell web site or call: 1-800-537-6945 USA 1-800-737-3360 Canada 1-815-235-6847 International FAX 1-815-235-6545 USA INTERNET www.honeywell.com/sensing info.sc@honeywell.com Description Integrated circuit humidity sensor, 0.100 in lead pitch SIP Integrated circuit humidity sensor, 0.050 in lead pitch SIP Integrated circuit humidity sensor, 0.100 in lead pitch SIP with calibration and data printout Integrated circuit humidity sensor, 0.050 in lead pitch SIP with calibration and data printout FIGURE 4: MOUNTING DIMENSIONS (for reference only) mm (in) HIH-3610-002 HIH-3610-004 4,27 (0.168) 4,27 (0.168) HIH-3610-001 HIH-3610-003 2,03 (0.080) 9,47 (0.373) 1,90 (0.075) 9,47 (0.373) 12,70 MIN (0.50) 12,19 MIN (0.480) OUT + 3X 0,38 (0.015) 2,54 (0.100) 2,54 (0.100) OUT + 3X 0,38 (0.015) 1,27 (0.050) 5,08 (0.200) Sensing and Control Honeywell 11 West Spring Street Freeport, Illinois 61032 Printed with Soy Ink on 50% Recycled Paper www.honeywell.com/sensing 009012-2-EN IL50 GLO 501 Printed in USA |
Price & Availability of HIH3610
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |