![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
MITSUBISHI INTELLIGENT POWER MODULES PM200DSA060 FLAT-BASE TYPE INSULATED PACKAGE A B G L C2E1 E2 C1 G G M U N 123 45 T - DIA. (4 TYP.) C 1234 5 P D N SIDE 1. VN1 2. SNR 3. CN1 4. VNC 5. FNO P SIDE 1. VP1 2. SPR 3. CP1 4. VPC 5. FPO Q - DIA. (2 TYP.) R - M5 THD. (3 TYP.) H P S S S S 0.64 MM SQ. PIN (10 TYP.) K J E F N VP1 VCC C1 TEMP OUT1 SR IN GND OUT2 SENS SINK Description: Mitsubishi Intelligent Power Modules are isolated base modules designed for power switching applications operating at frequencies to 20kHz. Built-in control circuits provide optimum gate drive and protection for the IGBT and free wheel-diode power devices. Features: Complete Output Power Circuit FPO SPR CP1 VPC VN1 FO C2E1 VCC TEMP OUT1 SR IN GND OUT2 SENS SINK Gate Drive Circuit Protection Logic - Short Circuit - Over Current - Over Temperature - Under Voltage Applications: Inverters UPS Motion/Servo Control Power Supplies Ordering Information: Example: Select the complete part number from the table below -i.e. PM200DSA060 is a 600V, 200 Ampere Intelligent Power Module. Type PM Current Rating Amperes 200 VCES Volts (x 10) 60 FNO SNR CN1 VNC FO E2 Outline Drawing and Circuit Diagram Dimensions A B C D E F G H J K Inches 4.33 3.660.010 1.77 1.34 Millimeters 110.0 93.00.25 45.0 34.0 Dimensions L M N P Q R S T U Inches 0.47 0.33 0.28 0.230 0.22 Dia. M5 Metric 0.100 0.08 Dia. 0.08 Millimeters 12.0 8.5 7.0 5.84 Dia. 5.5 M5 2.54 Dia. 2.0 2.0 1.14 +0.04/-0.02 29.0 +1/-0.5 1.02 0.98 0.702 0.55 0.51 26.0 25.0 17.84 14.0 13.0 Sep.2000 MITSUBISHI INTELLIGENT POWER MODULES PM200DSA060 FLAT-BASE TYPE INSULATED PACKAGE Absolute Maximum Ratings, Tj = 25C unless otherwise specified Symbol Power Device Junction Temperature Storage Temperature Case Operating Temperature Mounting Torque, M5 Mounting Screws Mounting Torque, M5 Main Terminal Screws Module Weight (Typical) Supply Voltage Protected by OC and SC (VD = 13.5 - 16.5V, Inverter Part) Isolation Voltage (Main Terminal to Baseplate, AC 1 min.) Tj Tstg TC -- -- -- VCC(prot.) Viso Ratings -20 to 150 -40 to 125 -20 to 100 1.47 ~ 1.96 1.47 ~ 1.96 340 400 2500 Units C C C N*m N*m Grams Volts Vrms Control Sector Supply Voltage (Applied between VP1-VPC, VN1-VNC) Input Voltage (Applied between CP1-VPC, CN1 -VNC) Fault Output Supply Voltage (Applied between Fpo-Vpc and Fno-Vnc ) Fault Output Current (Sink Current at FPO, FNO Terminal) VD VCIN VFO IFO 20 10 20 20 Volts Volts Volts mA IGBT Inverter Sector Collector-Emitter Voltage (VD = 15V, VCIN = 5V) Collector Current, (TC = 25C) Peak Collector Current, (TC = 25C) Supply Voltage (Applied between C1 - E2) Supply Voltage, Surge (Applied between C1 - E2) Collector Dissipation VCES IC ICP VCC VCC(surge) PC 600 200 400 450 500 595 Volts Amperes Amperes Volts Volts Watts Sep.2000 MITSUBISHI INTELLIGENT POWER MODULES PM200DSA060 FLAT-BASE TYPE INSULATED PACKAGE Electrical and Mechanical Characteristics, Tj = 25C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units Control Sector Over Current Trip Level Inverter Part Short Circuit Trip Level Inverter Part Over Current Delay Time Over Temperature Protection OC SC t off(OC) OT OTr Supply Circuit Under Voltage Protection UV UV r Supply Voltage Circuit Current VD ID Vth(on) Vth(off) f PWM IFO(H) IFO(L) Minimum Fault Output Pulse Width SXR Terminal Output Voltage tFO VSXR -20C T 125C -20C T 125C VD = 15V Trip Level Reset Level Trip Level Reset Level Applied between VP1-VPC, VN1-VNC VD = 15V, VCIN = 5V, VN1 -VNC VD = 15V, VCIN = 5V, VXP1-VXPC Input ON Threshold Voltage Input OFF Threshold Voltage PWM Input Frequency Fault Output Current Applied between CP1-VPC, CN1-VNC 3- Sinusoidal VD = 15V, VFO = 15V VD = 15V, VFO = 15V VD = 15V 310 400 -- 100 85 11.5 -- 13.5 -- -- 1.2 1.7 -- -- -- 1.0 400 560 5 110 95 12.0 12.5 15 19 19 1.5 2.0 15 -- 10 1.8 5.1 -- -- -- 120 105 12.5 -- 16.5 26 26 1.8 2.3 20 0.01 15 -- 5.6 Amperes Amperes s C C Volts Volts Volts mA mA Volts Volts kHz mA mA ms Volts -20CTj 125C, Rin = 6.8 k (SPR, SNR) 4.5 Sep.2000 MITSUBISHI INTELLIGENT POWER MODULES PM200DSA060 FLAT-BASE TYPE INSULATED PACKAGE Electrical and Mechanical Characteristics, Tj = 25C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units IGBT Inverter Sector Collector Cutoff Current ICES VEC VCE(sat) VCE = VCES, Tj = 25C VCE = VCES, Tj = 125C Emitter-Collector Voltage Collector-Emitter Saturation Voltage -IC = 200A, VD = 15V, VCIN = 5V VD = 15V, VCIN = 0V, IC = 200A VD = 15V, VCIN = 0V, IC = 200A, Tj = 125C Inductive Load Switching Times ton trr tC(on) toff tC(off) VD = 15V, VCIN = 0 5V VCC = 300V, IC = 200A Tj = 125C 0.5 -- -- -- -- 1.4 0.15 0.4 2.0 0.5 2.5 0.3 1.0 3.0 1.0 s s s s s -- -- -- -- -- -- -- 1.9 1.8 1.9 1 10 2.8 2.6 2.7 mA mA Volts Volts Volts Thermal Characteristics Characteristic Junction to Case Thermal Resistance Symbol Rth(j-c)Q Rth(j-c)F Contact Thermal Resistance Rth(c-f) Condition Each IGBT Each FWDi Case to Fin Per Module, Thermal Grease Applied Min. -- -- -- Typ. -- -- -- Max. 0.21 0.35 0.060 Units C/Watt C/Watt C/Watt Recommended Conditions for Use Characteristic Supply Voltage Symbol VCC VD Input ON Voltage Input OFF Voltage PWM Input Frequency Minimum Dead Time VCIN(on) VCIN(off) f PWM tdead Condition Applied across C1-E2 Terminals Applied between VP1-VPC, VN1-VNC Applied between CP1-VPC, CN1 -VNC Using Application Circuit Input Signal Value 0 ~ 400 15 1.5 0 ~ 0.8 Units Volts Volts Volts 4.0 ~ VSXR Volts 5 ~ 20 3.5 kHz s Sep.2000 MITSUBISHI INTELLIGENT POWER MODULES PM200DSA060 FLAT-BASE TYPE INSULATED PACKAGE SATURATION VOLTAGE CHARACTERISTICS (TYPICAL) COLLECTOR-EMITTER SATURATION VOLTAGE CHARACTERISTICS (TYPICAL) OUTPUT CHARACTERISTICS (TYPICAL) 3 COLLECTOR-EMITTER SATURATION VOLTAGE VCE(sat), (VOLTS) SATURATION VOLTAGE VCE(sat), (VOLTS) 3 COLLECTOR CURRENT, IC, (AMPERES) 300 Tj = 25oC VCIN = 15V 15 13 VD = 17V VD = 15V VCIN = 0V Tj = 25oC Tj = 125oC 2 2 200 1 1 IC = 200A VCIN = 0V Tj = 25oC Tj = 125oC 100 0 0 100 200 300 COLLECTOR CURRENT, IC, (AMPERES) 0 0 12 14 16 18 20 22 SUPPLY VOLTAGE, VD, (VOLTS) 0 0 1 2 3 COLLECTOR-EMITTER VOLTAGE, VCE, (VOLTS) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL) REVERSE RECOVERY CURRENT VS. COLLECTOR CURRENT (TYPICAL) 101 VCC = 300V VD = 15V SWITCHING TIMES, ton, toff, (s) 101 Inductive Load 100 VCC = 300V VD = 15V Irr 102 REVERSE RECOVERY CURRENT, Irr, (AMPERES) Tj = 25oC Tj = 125oC toff SWITCHING TIMES, tc(on), tc(off), (s) Inductive Load Tj = 25oC Tj = 125oC REVERSE RECOVERY TIME, trr, (s) trr 100 ton 100 tc(off) tc(on) 10-1 101 VCC = 300V VD = 15V Inductive Load Tj = 25oC Tj = 125oC 10-1 101 102 COLLECTOR CURRENT, IC, (AMPERES) 103 10-1 101 102 COLLECTOR CURRENT, IC, (AMPERES) 103 10-2 101 102 100 103 COLLECTOR REVERSE CURRENT, -IC, (AMPERES) DIODE FORWARD CHARACTERISTICS OVER CURRENT TRIP LEVEL VS. SUPPLY VOLTAGE (TYPICAL) OVER CURRENT TRIP LEVEL TEMPERATURE DEPENDENCY (TYPICAL) COLLECTOR REVERSE CURRENT, -IC, (AMPERES) 103 OVER CURRENT TRIP LEVEL % (NORMALIZED) 120 OVER CURRENT TRIP LEVEL % (NORMALIZED) 120 Tj = 25oC VD = 15V VD = 15V VCIN = 15V Tj = 25oC Tj = 125oC 100 80 60 40 20 10 0 100 80 102 60 40 101 0.4 0.8 1.2 1.6 2.0 2.4 0 0 12 14 16 18 20 -50 0 50 100 150 SUPPLY VOLTAGE, VD, (VOLTS) JUNCTION TEMPERATURE, Tj, (oC) EMITTER-COLLECTOR VOLTAGE, VEC, (VOLTS) Sep.2000 MITSUBISHI INTELLIGENT POWER MODULES PM200DSA060 FLAT-BASE TYPE INSULATED PACKAGE FAULT OUTPUT PULSE WIDTH VS. TEMPERATURE (TYPICAL) CONTROL SUPPLY VOLTAGE TRIP-RESET LEVEL TEMPERATURE DEPENDENCY (TYPICAL) TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (Each IGBT) TRANSIENT IMPEDANCE, Zth(j-c), (NORMALIZED VALUE) 120 FAULT OUTPUT PULSE WIDTH % (NORMALIZED) 15 VD = 15V UVt UVr 101 100 UV TRIP-RESET LEVEL, UVt, UVr, (VOLTS) 14 100 80 13 10-1 60 12 40 11 10-2 SINGLE PULSE STANDARD VALUE = Rth(j-c)Q = 0.21oC/W 0 -50 0 50 100 o 0 150 -50 0 50 100 o 150 10-3 10-3 10-2 10-1 TIME, (s) 100 101 JUNCTION TEMPERATURE, Tj, ( C) JUNCTION TEMPERATURE, Tj, ( C) TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (Each FWDi) TRANSIENT IMPEDANCE, Zth(j-c), (NORMALIZED VALUE) 101 100 10-1 10-2 SINGLE PULSE STANDARD VALUE = Rth(j-c)F = 0.35oC/W 10-3 10-3 10-2 10-1 TIME, (s) 100 101 Sep.2000 |
Price & Availability of PM200DSA060
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |