 SPANSION Flash Memory
Data Sheet
TM
September 2003
TM
This document specifies SPANSION memory products that are now offered by both Advanced Micro Devices and Fujitsu. Although the document is marked with the name of the company that originally developed the specification, these products will be offered to customers of both AMD and Fujitsu.
Continuity of Specifications
There is no change to this datasheet as a result of offering the device as a SPANSION revisions will occur when appropriate, and changes will be noted in a revision summary.
TM
product. Future routine
Continuity of Ordering Part Numbers
AMD and Fujitsu continue to support existing part numbers beginning with "Am" and "MBM". To order these products, please use only the Ordering Part Numbers listed in this document.
For More Information
Please contact your local AMD or Fujitsu sales office for additional information about SPANSION solutions.
TM
memory
FUJITSU SEMICONDUCTOR DATA SHEET
DS05-20882-5E
FLASH MEMORY
CMOS
64M (4M x 16) BIT
MBM29LV650UE90 MBM29LV651UE90
s DESCRIPTION
The MBM29LV650UE/651UE is a 64M-bit, 3.0 V-only Flash memory organized as 4M words of 16 bits each. The device is designed to be programmed in system with the standard system 3.0 V VCC supply. 12.0 V VPP and 5.0 V VCC are not required for write or erase operations. The devices can also be reprogrammed in standard EPROM programmers. To eliminate bus contention the devices have separate chip enable (CE), write enable (WE), and output enable (OE) controls. (Continued)
s PRODUCT LINE UP
Part No. Ambient Temperature Address Access Time (Max) Power Supply Voltage Operating mode(@5 MHz) Power Consumption (Max) Erase/Programming mode CMOS Standby mode MBM29LV650UE90/651UE90 -40C to +85C 90 ns 3.3 V 0.3 V 58 mW 126 mW 0.018 mW
s PACKAGES
48-pin plastic TSOP (1)
Marking Side
Marking Side
(FPT-48P-M19)
(FPT-48P-M20)
MBM29LV650UE90/651UE90
(Continued)
The MBM29LV650UE/651UE is entirely command set compatible with JEDEC single-power-supply Flash standard. Commands are written to the command register using standard microprocessor write timings. Register contents serve as input to an internal state-machine which controls the erase and programming circuitry. Write cycles also internally latch addresses and data needed for the programming and erase operations. Typically, each sector can be programmed and verified in about 0.5 seconds. A sector is typically erased and verified in 1.0 second. (If already completely preprogrammed.) The device also features a sector erase architecture. The sector mode allows each sector to be erased and reprogrammed without affecting other sectors. The MBM29LV650UE/651UE is erased when shipped from the factory. Internally generated and regulated voltages are provided for the program and erase operations. A low VCC detector automatically inhibits write operations on the loss of power. The end of program or erase is detected by Data Polling of DQ7, by the Toggle Bit feature on DQ6. Once the end of a program or erase cycle has been completed, the devices internally reset to the read mode. The devices electrically erase all bits within a sector simultaneously via Fowler-Nordhiem tunneling. The words are programmed one word at a time using the EPROM programming mechanism of hot electron injection.
s FEATURES
* 0.23 m Process Technology * Single 3.0 V read, program and erase Minimizes system level power requirements * Compatible with JEDEC-standards Uses same software commands with single-power supply Flash * Address don't care during the command sequence * Industry-standard pinouts 48-pin TSOP (1) (Package suffix: TN - Normal Bend Type, TR - Reversed Bend Type) * Minimum 100,000 program/erase cycles * High performance 90 ns maximum access time * Flexible sector architecture 128 32 K word sectors Any combination of sectors can be concurrently erased. Also supports full chip erase. * HiddenROM region 128 words of HiddenROM, accessible through a new "HiddenROM Enable" command sequence Factory serialized and protected to provide a secure electronic serial number (ESN) * WP input pin At VIL, allows protection of first or last 32 K word sector, regardless of sector protection/unprotection status At VIH, allows removal of protection MBM29LV650UE: has the function to protect the last 32 K word sector (SA 127). MBM29LV651UE: has the function to protect the first 32 K word sector (SA 0). * ACC input pin At VACC, increases program performance * Embedded EraseTM* Algorithms Automatically pre-programs and erases the chip or any sector * Embedded programTM* Algorithms Automatically writes and verifies data at specified address * Data Polling and Toggle Bit feature for detection of program or erase cycle completion (Continued) *: Embedded EraseTM and Embedded ProgramTM are trademarks of Advanced Micro Devices, Inc. 2
MBM29LV650UE90/651UE90
(Continued) * Automatic sleep mode When addresses remain stable, automatically switches themselves to low power mode * Low VCC write inhibit 2.5 V * Erase Suspend/Resume Suspends the erase operation to allow a read data and/or program in another sector within the same device * Sector group protection Hardware method disables any combination of sector groups from program or erase operations * Sector Group Protection Set function by Extended sector protect command * Fast Programming Function by Extended Command * Temporary sector group unprotection Temporary sector group unprotection via the RESET pin This feature allows code changes in previously locked sectors * In accordance with CFI (Common Flash Memory Interface)
3
MBM29LV650UE90/651UE90
s PIN ASSIGNMENTS
TSOP(I) A15 A14 A13 A12 A11 A10 A9 A8 A21 A20 WE RESET ACC WP A19 A18 A17 A7 A6 A5 A4 A3 A2 A1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 (Marking Side) 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 A16 VCCq VSS DQ15 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VCC DQ11 DQ3 DQ10 DQ2 DQ9 DQ1 DQ8 DQ0 OE VSS CE A0
MBM29LV650UE/651UE Normal Bend
FPT-48P-M19 A1 A2 A3 A4 A5 A6 A7 A17 A18 A19 WP ACC RESET WE A20 A21 A8 A9 A10 A11 A12 A13 A14 A15 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 (Marking Side) 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 A0 CE VSS OE DQ0 DQ8 DQ1 DQ9 DQ2 DQ10 DQ3 DQ11 VCC DQ4 DQ12 DQ5 DQ13 DQ6 DQ14 DQ7 DQ15 VSS VCCq A16
MBM29LV650UE/651UE Reverse Bend
FPT-48P-M20
4
MBM29LV650UE90/651UE90
s PIN DESCRIPTION
Pin A0 to A21 DQ0 to DQ15 CE OE WE WP RESET ACC VCCq VSS VCC Address Inputs Data Inputs/Outputs Chip Enable Output Enable Write Enable Hardware Write Protection Hardware Reset Pin/Temporary Sector Group Unprotection Program Acceleration Output Buffer Power Device Ground Device Power Supply Function
5
MBM29LV650UE90/651UE90
s BLOCK DIAGRAM
DQ0 to DQ15
VCC VSS
Erase Voltage Generator
Input/Output Buffers
VCCq
WE RESET WP ACC
State Control
Command Register
Program Voltage Generator
CE OE
Chip Enable Output Enable Logic
STB
Data Latch
STB
Y-Decoder
Y-Gating
Timer for Program/Erase
Address Latch
X-Decoder
Cell Matrix
A0 to A21
6
MBM29LV650UE90/651UE90
s LOGIC SYMBOL
22 A21 to A0 DQ 15 to DQ 0 CE OE WE WP RESET ACC 16
VCCq
7
MBM29LV650UE90/651UE90
s DEVICE BUS OPERATION
MBM29LV650UE/651UE User Bus Operations Table Operation Auto-Select Manufacture Code*1 Auto-Select Device Code*1 Read*3 Standby Output Disable Write (Program/Erase) Enable Sector Group Protection*2, *4 Verify Sector Group Protection*2, *4 Temporary Sector Group Unprotection*5 Reset (Hardware)/Standby Boot Block Sector Write Protection*6 Legend: L = VIL, H = VIH, X = VIL or VIH. CE L L L H L L L L X X X OE L L L X H H VID L X X X H X X X WE H H H X H L A0 L H A0 X X A0 L L X X X A1 L L A1 X X A1 H H X X X A6 L L A6 X X A6 L L X X X A9 VID VID A9 X X A9 VID VID X X X DQ0 to DQ15 RESET WP Code Code DOUT High-Z High-Z DIN X Code X High-Z X H H H H H H H H VID L X X X X X X X X X X X L
= Pulse input.
*1 : Manufacturer and device codes may also be accessed via a command register write sequence. *2 : Refer to "Sector Group Protection" in s FUNCTIONAL DESCRIPTION. *3 : WE can be VIL if OE is VIL, OE at VIH initiates the write operations. *4 : VCC = + 3.3 V 10% *5 : Also used for the extended sector group protection. *6 : Either side of boot block sector are protected.
8
MBM29LV650UE90/651UE90
MBM29LV650UE/651UE Command Definitions Table First Bus Second Bus Third Bus Fourth Bus Fifth Bus Sixth Bus Write Cycle Write Cycle Write Cycle Read/Write Write Cycle Write Cycle Cycle Addr. Data Addr. Data Addr. Data Addr. Data -- XXXh XXXh XXXh XXXh XXXh -- -- XXXh -- -- SPA -- XXXh XXXh XXXh -- F0h 90h A0h 80h 80h -- -- 20h -- -- -- RA* IA* PA
7 7
Command Sequence Read/Reset* Read/Reset* Autoselect Program Chip Erase Sector Erase Erase Suspend Erase Resume Set to Fast Mode Fast Program *
2 1 1
Bus Write Cycles Req'd Addr. Data Addr. Data 1 3 3 4 6 6 1 1 3 2 2 4 1 3 4 4 XXXh F0h -- -- 55h 55h 55h 55h 55h -- -- 55h PD XXXh AAh XXXh XXXh AAh XXXh XXXh AAh XXXh XXXh AAh XXXh XXXh AAh XXXh XXXh XXXh XXXh XXXh XXXh XXh B0h 30h A0h 90h 60h 98h -- -- PA
-- RD* ID* PD
7 7
-- -- -- --
-- -- -- -- 55h 55h -- -- -- -- -- -- -- -- -- --
-- -- -- -- XXXh SA -- -- -- -- -- -- -- -- -- --
-- -- -- -- 10h 30h -- -- -- -- -- -- -- -- -- --
XXXh AAh XXXh XXXh AAh XXXh -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
XXXh AAh XXXh
Reset from Fast Mode *2 Extended Sector Group Protection *3 Query *4
HiddenROM Entry
XXXh F0h*6 SPA -- 60h -- 55h 55h 55h
40h SPA*7 SD*7 -- 88h A0h 90h -- -- PA XXXh -- -- PD 00h
XXXh AAh XXXh XXXh AAh XXXh XXXh AAh XXXh
HiddenROM Program *5
HiddenROM Exit *5
*1: Both of these reset commands are equivalent. *2: This command is valid during fast mode. *3: This command is valid while RESET = VID. *4: The valid addresses are A6 to A0. *5: This command is valid during HiddenROM mode. *6: The data "00" is also acceptable. *7 : The fourth bus cycle is only for read. Notes : * Address bits = X = "H" or "L" for all address commands except for Program Address (PA) and Sector Address (SA). * Bus operations are defined in "User Bus Operations Table". * RA = Address of the memory location to be read. IA = Autoselect read address sets both the bank address specified at (A19, A18, A17, A16, A15) and all the other A6, A1, A0, (A-1) . PA = Address of the memory location to be programmed. Addresses are latched on the falling edge of the write pulse. SA = Address of the sector to be erased. The combination of A21, A20, A19, A18, A17,A16, and A15 will uniquely select any sector. * RD = Data read from location RA during read operation. ID = Device code/manufacture code for the address located by IA. PD = Data to be programmed at location PA. Data is latched on the rising edge of write pulse. * SPA = Sector group address to be protected. Set sector group address (SA) and (A6, A1, A0) = (0, 1, 0). SD = Sector group protection verify data. Output 01h at protected sector group addresses and output 00h at unprotected sector group addresses. * Both Read/Reset commands are functionally equivalent, resetting the device to the read mode. * Command combinations not described in "MBM29LV650UE/651UE Command Definitions Table" are illegal. 9
MBM29LV650UE90/651UE90
MBM29LV650UE/651UE Sector Group Protection Verify Autoselect Codes Table Type Manufacturer's Code Device Code MBM29LV650UE/651UE Sector Group Protection Extended Code MBM29LV650UE X MBM29LV651UE VIL VIH VIH 0000h A17 to A21 X X Sector Group Address A6 VIL VIL VIL A1 VIL VIL VIH A0 VIL VIH VIL Code (HEX) 04h 22D7h 01h * 0010h
*: Outputs 01h at protected sector group addresses and outputs 00h at unprotected sector group addresses. Extended Autoselect Code Table Type Manufacturer's Code Code 04h
DQ15 DQ14 DQ13 DQ12 DQ11 DQ10 DQ9 DQ8 DQ7 DQ6 DQ5 DQ4 DQ3 DQ2 DQ1 DQ0
0 0 0 0 0
0 0 0 0 0
0 1 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 1 0 0 0
0 0 0 0 0
0 1 0 0 0
0 1 0 0 0
0 0 0 0 0
0 1 0 1 0
0 0 0 0 0
1 1 0 0 0
0 1 0 0 0
0 1 1 0 0
Device MBM29LV650UE/ 22D7h 651UE Code Sector Group Protection 01h
Extend MBM29LV650UE 0010h Code MBM29LV651UE 0000h
10
MBM29LV650UE90/651UE90
s FLEXIBLE SECTOR-ERASE ARCHITECTURE
Sector Address Table Sector Address SA0 SA1 SA2 SA3 SA4 SA5 SA6 SA7 SA8 SA9 SA10 SA11 SA12 SA13 SA14 SA15 SA16 SA17 SA18 SA19 SA20 SA21 SA22 SA23 SA24 SA25 SA26 SA27 SA28 SA29 SA30 SA31 A21 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 A20 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 A19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 A18 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 A17 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 A16 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 A15 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Sector Size (K words) 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 Address Range 000000h to 007FFFh 008000h to 00FFFFh 010000h to 017FFFh 018000h to 01FFFFh 020000h to 027FFFh 028000h to 02FFFFh 030000h to 037FFFh 038000h to 03FFFFh 040000h to 047FFFh 048000h to 04FFFFh 050000h to 057FFFh 058000h to 05FFFFh 060000h to 067FFFh 068000h to 06FFFFh 070000h to 077FFFh 078000h to 07FFFFh 080000h to 087FFFh 088000h to 08FFFFh 090000h to 097FFFh 098000h to 09FFFFh 0A0000h to 0A7FFFh 0A8000h to 0AFFFFh 0B0000h to 0B7FFFh 0B8000h to 0BFFFFh 0C0000h to 0C7FFFh 0C8000h to 0CFFFFh 0D0000h to 0D7FFFh 0D8000h to 0DFFFFh 0E0000h to 0E7FFFh 0E8000h to 0EFFFFh 0F0000h to 0F7FFFh 0F8000h to 0FFFFFh
(Continued)
11
MBM29LV650UE90/651UE90
Sector Address SA32 SA33 SA34 SA35 SA36 SA37 SA38 SA39 SA40 SA41 SA42 SA43 SA44 SA45 SA46 SA47 SA48 SA49 SA50 SA51 SA52 SA53 SA54 SA55 SA56 SA57 SA58 SA59 SA60 SA61 SA62 SA63
A21 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
A20 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
A19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
A18 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
A17 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
A16 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
A15 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
Sector Size (K words) 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32
Address Range 100000h to 107FFFh 108000h to 10FFFFh 110000h to 117FFFh 118000h to 11FFFFh 120000h to 127FFFh 128000h to 12FFFFh 130000h to 137FFFh 138000h to 13FFFFh 140000h to 147FFFh 148000h to 14FFFFh 150000h to 157FFFh 158000h to 15FFFFh 160000h to 167FFFh 168000h to 16FFFFh 170000h to 177FFFh 178000h to 17FFFFh 180000h to 187FFFh 188000h to 18FFFFh 190000h to 197FFFh 198000h to 19FFFFh 1A0000h to 1A7FFFh 1A8000h to 1AFFFFh 1B0000h to 1B7FFFh 1B8000h to 1BFFFFh 1C0000h to 1C7FFFh 1C8000h to 1CFFFFh 1D0000h to 1D7FFFh 1D8000h to 1DFFFFh 1E0000h to 1E7FFFh 1E8000h to 1EFFFFh 1F0000h to 1F7FFFh 1F8000h to 1FFFFFh
(Continued)
12
MBM29LV650UE90/651UE90
Sector Address SA64 SA65 SA66 SA67 SA68 SA69 SA70 SA71 SA72 SA73 SA74 SA75 SA76 SA77 SA78 SA79 SA80 SA81 SA82 SA83 SA84 SA85 SA86 SA87 SA88 SA89 SA90 SA91 SA92 SA93 SA94 SA95
A21 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
A20 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
A19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
A18 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
A17 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
A16 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
A15 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
Sector Size (K words) 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32
Address Range 200000h to 207FFFh 208000h to 20FFFFh 210000h to 217FFFh 218000h to 21FFFFh 220000h to 227FFFh 228000h to 22FFFFh 230000h to 237FFFh 238000h to 23FFFFh 240000h to 247FFFh 248000h to 24FFFFh 250000h to 257FFFh 258000h to 25FFFFh 260000h to 267FFFh 268000h to 26FFFFh 270000h to 277FFFh 278000h to 27FFFFh 280000h to 287FFFh 288000h to 28FFFFh 290000h to 297FFFh 298000h to 29FFFFh 2A0000h to 2A7FFFh 2A8000h to 2AFFFFh 2B0000h to 2B7FFFh 2B8000h to 2BFFFFh 2C0000h to 2C7FFFh 2C8000h to 2CFFFFh 2D0000h to 2D7FFFh 2D8000h to 2DFFFFh 2E0000h to 2E7FFFh 2E8000h to 2EFFFFh 2F0000h to 2F7FFFh 2F8000h to 2FFFFFh
(Continued)
13
MBM29LV650UE90/651UE90
(Continued)
Sector Address SA96 SA97 SA98 SA99 SA100 SA101 SA102 SA103 SA104 SA105 SA106 SA107 SA108 SA109 SA110 SA111 SA112 SA113 SA114 SA115 SA116 SA117 SA118 SA119 SA120 SA121 SA122 SA123 SA124 SA125 SA126 SA127 A21 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 A20 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 A19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 A18 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 A17 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 A16 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 A15 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Sector Size (K words) 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 Address Range 300000h to 307FFFh 308000h to 30FFFFh 310000h to 317FFFh 318000h to 31FFFFh 320000h to 327FFFh 328000h to 32FFFFh 330000h to 337FFFh 338000h to 33FFFFh 340000h to 347FFFh 348000h to 34FFFFh 350000h to 357FFFh 358000h to 35FFFFh 360000h to 367FFFh 368000h to 36FFFFh 370000h to 377FFFh 378000h to 37FFFFh 380000h to 387FFFh 388000h to 38FFFFh 390000h to 397FFFh 398000h to 39FFFFh 3A0000h to 3A7FFFh 3A8000h to 3AFFFFh 3B0000h to 3B7FFFh 3B8000h to 3BFFFFh 3C0000h to 3C7FFFh 3C8000h to 3CFFFFh 3D0000h to 3D7FFFh 3D8000h to 3DFFFFh 3E0000h to 3E7FFFh 3E8000h to 3EFFFFh 3F0000h to 3F7FFFh 3F8000h to 3FFFFFh
14
MBM29LV650UE90/651UE90
Sector Group Address Table Sector Group Address SGA0 SGA1 SGA2 SGA3 SGA4 SGA5 SGA6 SGA7 SGA8 SGA9 SGA10 SGA11 SGA12 SGA13 SGA14 SGA15 SGA16 SGA17 SGA18 SGA19 SGA20 SGA21 SGA22 SGA23 SGA24 SGA25 SGA26 SGA27 SGA28 SGA29 SGA30 SGA31 A21 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 A20 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 A19 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 A18 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 A17 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Sector Group Size (K words) 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 Sectors SA0 to SA3 SA4 to SA7 SA8 to SA11 SA12 to SA15 SA16 to SA19 SA20 to SA23 SA24 to SA27 SA28 to SA31 SA32 to SA35 SA36 to SA39 SA40 to SA43 SA44 to SA47 SA48 to SA51 SA52 to SA55 SA56 to SA59 SA60 to SA63 SA64 to SA67 SA68 to SA71 SA72 to SA75 SA76 to SA79 SA80 to SA83 SA84 to SA87 SA88 to SA91 SA92 to SA95 SA96 to SA99 SA100 to SA103 SA104 to SA107 SA108 to SA111 SA112 to SA115 SA116 to SA119 SA120 to SA123 SA124 to SA127
15
MBM29LV650UE90/651UE90
Common Flash Memory Interface Code Table
Description A6 to A0 DQ15 to DQ0 Description A6 to A0 DQ15 to DQ0
Query-unique ASCII string "QRY" Primary OEM Command Set 02h: AMD/FJ standard type Address for Primary Extended Table Alternate OEM Command Set (00h = not applicable) Address for Alternate OEM Extended Table VCC Min. (write/erase) DQ7 to DQ4: 1 V, DQ3 to DQ0: 100 mV VCC Max. (write/erase) DQ7 to DQ4: 1 V, DQ3 to DQ0: 100 mV VPP Min. voltage VPP Max. voltage Typical timeout per single byte/ word write 2N s Typical timeout for Min size buffer write 2N s Typical timeout per individual sector erase 2N ms Typical timeout for full chip erase 2N ms Max timeout for byte/word write 2N times typical (s) Max timeout for buffer write 2N times typical (s) Max timeout per individual sector erase 2N times typical (s) Max timeout for full chip erase 2N times typical (ms) Device Size = 2N byte Flash Device Interface description 1h : x 16 Max number of byte in multi-byte write = 2N Number of Erase Block Regions within device
10h 11h 12h 13h 14h 15h 16h 17h 18h 19h 1Ah 1Bh
0051h 0052h 0059h 0002h 0000h 0040h 0000h 0000h 0000h 0000h 0000h 0027h
Erase Block Region 1 Information bit 15 to bit 0 : y = number of sectors bit 31 to bit 16 : z = size (zx256 bytes) Erase Block Region 2 Information bit 15 to bit 0 : y = number of sectors bit 31 to bit 16 : z = size (zx256 bytes) Query-unique ASCII string "PRI" Major version number, ASCII Minor version number, ASCII Address Sensitive Unlock 00h = Required Erase Suspend 00h = Not supported 01h = To read only 02h = To Read & Write Sector Protection 00h = Not Supported X = Number of sectors in per group Sector Temporary Unprotection 00h = Not supported 01h = Supported Sector Protection Algorithm Number of Sector for Bank 2 00h = Not Supported Burst Mode Type 00h = Not Supported Page Mode Type 00h = Not Supported VACC (Acceleration) Supply Minimum 00h = Not Supported, DQ7 to DQ4: 1 V, DQ3 to DQ0: 100 mV VACC (Acceleration) Supply Maximum 00h = Not Supported, DQ7 to DQ4: 1 V, DQ3 to DQ0: 100 mV Boot Type 04h = MBM29LV651UE 05h = MBM29LV650UE
2Dh 2Eh 2Fh 30h 31h 32h 33h 34h 40h 41h 42h 43h 44h 45h
007Fh 0000h 0000h 0001h 0000h 0000h 0000h 0000h 0050h 0052h 0049h 0031h 0031h 0001h
1Ch 1Dh 1Eh 1Fh 20h 21h 22h 23h 24h 25h 26h 27h 28h 29h 2Ah 2Bh 2Ch
0036h 0000h 0000h 0004h 0000h 000Ah 0000h 0005h 0000h 0004h 0000h 0017h 0001h 0000h 0000h 0000h 0001h
46h
0002h
47h
0004h
48h 49h 4Ah 4Bh 4Ch
0001h 0004h 0000h 0000h 0000h
4Dh
00B5h
4Eh
00C5h
4Fh
00XXh
16
MBM29LV650UE90/651UE90
s FUNCTIONAL DESCRIPTION
Read Mode
The MBM29LV650UE/651UE have two control functions required to obtain data at the outputs. CE is the power control and used for a device selection. OE is the output control and used to gate data to the output pins if a device is selected. Address access time (tACC) is equal to the delay from stable addresses to valid output data. The chip enable access time (tCE) is the delay from stable addresses and stable CE to valid data at the output pins. The output enable access time (tOE) is the delay from the falling edge of OE to valid data at the output pins, assuming the addresses have been stable for at least tACC-tOE time. When reading out a data without changing addresses after power-up, it is necessary to input hardware reset or to change CE pin from "H" or "L".
Standby Mode
There are two ways to implement the standby mode on the MBM29LV650UE/651UE devices, one using both the CE and RESET pins; the other via the RESET pin only. When using both pins, a CMOS standby mode is achieved with CE and RESET inputs both held at VCC 0.3 V. Under this condition the current consumed is less than 5 A Max. During Embedded Algorithm operation, VCC active current (ICC2) is required even CE = "H". The device can be read with standard access time (tCE) from either of these standby modes. When using the RESET pin only, CMOS standby mode is achieved with RESET input held at VSS 0.3 V (CE = "H" or "L"). Under this condition the current consumed is less than 5 A Max. Once the RESET pin is taken high, the device requires tRH of wake up time before outputs are valid for read access. In the standby mode the outputs are in the high impedance state, independent of the OE input.
Automatic Sleep Mode
Automatic sleep mode works to restrain power consumption during read-out of MBM29LV650UE/651UE data. This is effective with an application requesting low power consumption such as handy terminals. To activate this mode, MBM29LV650UE/651UE automatically switch themselves to low power mode when MBM29LV650UE/651UE addresses remain stable during access fine of 150 ns. It is not necessary to control CE, WE, and OE on the mode. Under the mode, the current consumed is typically 1 A (CMOS Level). Since the data are latched during this mode, the data are read out continuously. If the addresses are changed, the mode is canceled automatically and MBM29LV650UE/651UE read out the data for changed addresses.
Output Disable
With the OE input at a logic high level (VIH), output from the devices are disabled. This causes the output pins to be in a high impedance state.
Autoselect
Autoselect mode allows the reading out of a binary code from the devices and identifies its manufacturer and type. This mode is intended for use by programming equipment for the purpose of automatically matching the devices to be programmed with its corresponding programming algorithm. To activate this mode, the programming equipment must force VID on address pin A9. Two identifier words may then be sequenced from the devices outputs by toggling address A0 from VIL to VIH. All addresses are DON'T CARES except A0, A1, and A6. (recommend to set VIL for other addresses pins.) The manufacturer and device codes may also be read via the command register, for instances when the MBM29LV650UE/651UE are erased or programmed in a system without access to high voltage on the A9 pin. The command sequence is illustrated in "MBM29LV650UE/651UE Command Definitions Table" in s DEVICE BUS OPERATION. (Refer to "Autoselect Command" in s COMMAND DEFINITIONS.) Word 0 (A0 = VIL) represents the manufacturer's code (Fujitsu = 04h) and word 1 (A0 = VIH) represents the device identifier code (MBM29LV650UE/651UE = 22D7h). These two words are given in "MBM29LV650UE/651UE Sector Group Protection Verify Autoselect Codes Table" and "Extended Autoselect Code Table" in s DEVICE BUS OPERATION. All identifiers for manufactures and device will exhibit odd parity with DQ7 defined as the parity bit. In order to read the proper device codes when executing the autoselect, A1 must be VIL. 17
MBM29LV650UE90/651UE90
Write
Device erasure and programming are accomplished via the command register. The contents of the register serve as inputs to the internal state machine. The state machine outputs dictate the function of the device. The command register itself does not occupy any addressable memory location. The register is a latch used to store the commands, along with the address and data information needed to execute the command. The command register is written by bringing WE to VIL, while CE is at VIL and OE is at VIH. Addresses are latched on the falling edge of WE or CE, whichever starts later; while data is latched on the rising edge of WE or CE, whichever starts first. Standard microprocessor write timings are used. Refer to s AC CHARACTERISTICS and s TIMING DIAGRAM.
Sector Group Protection
The MBM29LV650UE/651UE feature hardware sector group protection. This feature will disable both program and erase operations in any combination of 32 sector groups of memory. Each sector group consists of 4 successive sectors. (See "Sector Group Address Table" in s FLEXIBLE SECTOR-ERASE ARCHITECTURE). The sector group protection feature is enabled using programming equipment at the user's site. The device is shipped with all sector groups unprotected. To activate this mode, the programming equipment must force VID on address pin A9 and control pin OE, CE = VIL and A0 = A6 = VIL, A1 = VIH. The sector group addresses (A21, A20, A19, A18, and A17) should be set to the sector to be protected. "Sector Group Address Table" in s FLEXIBLE SECTOR-ERASE ARCHITECTURE defines the sector address for each of the 32 individual sectors. Programming of the protection circuitry begins on the falling edge of the WE pulse and is terminated with the rising edge of the same. Sector group addresses must be held constant during the WE pulse. See "(9) Sector Group Protection Timing Diagram" in s TIMING DIAGRAM and "(5) Sector Group Protection Algorithm" in s FLOW CHART for sector group protection waveforms and algorithm. To verify programming of the protection circuitry, the programming equipment must force VID on address pin A9 with CE and OE at VIL and WE at VIH. Scanning the sector group addresses (A21, A20, A19, A18, and A17) while (A6, A1, A0) = (0, 1, 0) will produce a logic "1" code at device output DQ0 for a protected sector. Otherwise the device will read 00h for unprotected sector. In this mode, the lower order addresses, except for A0, A1, and A6 are DON'T CARES (recommend to set VIL for other addresses pins). See "MBM29LV650UE/651UE User Bus Operations Table" and "MBM29LV650UE/651UE Sector Group Protection Verify Autoselect Codes Table" in s DEVICE BUS OPERATION for Autoselect codes. It is also possible to determine if a sector group is protected in the system by writing an Autoselect command. See "Extended Command (3) Extended Sector Group Protection" in s COMMAND DEFINITIONS.
Temporary Sector Group Unprotection
This feature allows temporary unprotection of previously protected sector groups of the MBM29LV650UE/651UE devices in order to change data. The Sector Group Unprotection mode is activated by setting the RESET pin to high voltage (VID). During this mode, formerly protected sector groups can be programmed or erased by selecting the sector group addresses. Once the VID is taken away from the RESET pin, all the previously protected sector groups will be protected again. Refer to "(9) Sector Group Protection Timing Diagram" in s TIMING DIAGRAM. The MBM29LV650UE/651UE also have Extended Sector Group Protection function. See s COMMAND DEFINITIONS. This temporary sector group unprotect mode is disabled whenever the chip is in the HiddenROM mode. This area cannot be programmed within this mode. Once this area is programmed, protection is for good.
18
MBM29LV650UE90/651UE90
RESET
Hardware Reset Pin
The MBM29LV650UE/651UE devices may be reset by driving the RESET pin to VIL. The RESET pin has a pulse requirement and has to be kept low (VIL) for at least "tRP" in order to properly reset the internal state machine. Any operation in the process of being executed will be terminated and the internal state machine will be reset to the read mode "tREADY" after the RESET pin is driven low. Furthermore, once the RESET pin goes high, the devices require an additional "tRH" before it will allow read access. When the RESET pin is low, the devices will be in the standby mode for the duration of the pulse and all the data output pins will be tri-stated. If a hardware reset occurs during a program or erase operation, the data at that particular location will be corrupted.
Write Protect (WP)
The Write Protection function provides a hardware method of protecting certain "outermost" 32 K word sector without using VID. If the system asserts VIL on the WP pin, the device disables program and erase functions in the "outermost" 32 K word sector independently of the protection status of this sector. The outermost 32 K word sector is the highest addresses in MBM29LV650UE, or the lowest addresses in MBM29LV651UE. (MBM29LV650UE: SA127, MBM29LV651UE: SA0) If the system asserts VIH on the WP pin, the device reverts to whether the outermost 32 K word sector was last set to be protected or unprotected. That is, sector protection or unprotection for this sector depends on whether this was last protected or unprotected using the method described in "Sector protection/unprotection".
Accelerated Program Operation
MBM29LV650UE/651UE offer accelerated program operation which enables the programming in high speed. If the system asserts VACC to the ACC pin, the device automatically enters the acceleration mode and the time required for program operation will reduce to about 60%. This function is primarily intended to allow high speed program, so caution is needed as the sector group will temporarily be unprotected. The system would use a fast program command sequence when programming during acceleration mode. It is unnecessary to set command to fast mode and to reset command from fast mode. When the device enters the acceleration mode, the device automatically set to fast mode. Therefore, the present sequence could be used for programming and detection of completion during acceleration mode. Removing VACC from the ACC pin returns the device to normal operation. Do not remove VACC from the ACC pin during programming. Erase operation during Accelerated Program Operation is strictly prohibited.
19
MBM29LV650UE90/651UE90
s COMMAND DEFINITIONS
Device operations are selected by writing specific address and data sequences into the command register. Writing incorrect data values or writing them in the improper sequence will reset the devices to the read mode. The valid register command sequences is defined in "MBM29LV650UE/651UE Command Definitions Table" in s DEVICE BUS OPERATION Note that the Erase Suspend (B0h) and Erase Resume (30h) commands are valid only while the Sector Erase operation is in progress. Moreover both Read/Reset commands are functionally equivalent, resetting the device to the read mode. Please note that commands are always written at DQ0 to DQ7 and DQ8 to DQ15 bits are ignored.
Read/Reset Command
In order to return from Autoselect mode or Exceeded Timing Limits to Read/Reset mode, the Read/Reset operation is initiated by writing the Read/Reset command sequence into the command register. Microprocessor read cycles retrieve array data from the memory. The devices remain enabled for reads until the command register contents are altered. The devices will automatically power up in the Read/Reset state. In this case, a command sequence is not required to read data. Standard microprocessor read cycles will retrieve array data. This default value ensures that no spurious alteration of the memory content occurs during the power transition. Refer to the s AC CHARACTERISTICS and s TIMING DIAGRAM for the specific timing parameters.
Autoselect Command
Flash memories are intended for use in applications where the local CPU alters memory contents. As such, manufacture and device codes must be accessible while the devices reside in the target system. PROM programmers typically access the signature codes by raising A9 to a high voltage. However, multiplexing high voltage onto the address lines is not generally desired system design practice. The device contains an Autoselect command operation to supplement traditional PROM programming methodology. The operation is initiated by writing the Autoselect command sequence into the command register. The Autoselect command sequence is initiated by first writing two unlock cycles. This is followed by a third write cycle that contains the address and the Autoselect command. Then the manufacture and device codes can be read from the address, and an actual data of memory cell can be read from the another address. Following the command write, a read cycle from address XX00h retrieves the manufacture code of 04h. A read cycle from address XX01h returns the device code (MBM29LV650UE/651UE = 22D7h). A read cycle from address XX03h returns the Extended Code (MBM29LV650UE = 0010h, MBM29LV651UE = 0000h). (See "MBM29LV650UE/651UE Sector Group Protection Verify Autoselect Codes Table" in s DEVICE BUS OPERATION.) All manufacturer and device codes will exhibit odd parity with DQ7 defined as the parity bit. Sector state (protection or unprotection) will be informed by address XX02h. Scanning the sector group addresses (A21, A20, A19, A18, and A17) while (A6, A1, A0) = (0, 1, 0) will produce a logic "1" at device output DQ0 for a protected sector group. The programming verification should be performed by verify sector group protection on the protected sector. (See "User Bus Operations Table" in s DEVICE BUS OPERATION.) To terminate the operation, it is necessary to write the Read/Reset command sequence into the register, and also to write the Autoselect command during the operation, execute it after writing Read/Reset command sequence.
20
MBM29LV650UE90/651UE90
Word Programming
The devices are programmed on a word-by-word basis. Programming is a four bus cycle operation. There are two "unlock" write cycles. These are followed by the program set-up command and data write cycles. Addresses are latched on the falling edge of CE or WE, whichever happens later and the data is latched on the rising edge of CE or WE, whichever happens first. The rising edge of CE or WE (whichever happens first) begins programming. Upon executing the Embedded Program Algorithm command sequence, the system is not required to provide further controls or timings. The device will automatically provide adequate internally generated program pulses and verify the programmed cell margin. The system can determine the status of the program operation by using DQ7 (Data Polling), and DQ6 (Toggle Bit). (See "Write Operation Status".) The Data Polling and Toggle Bit must be performed at the memory location which is being programmed. The automatic programming operation is completed when the data on DQ7 is equivalent to data written to this bit at which time the devices return to the read mode and addresses are no longer latched. Therefore, the devices require that a valid address to the devices be supplied by the system at this particular instance of time. Hence, Data Polling must be performed at the memory location which is being programmed. Any commands written to the chip during this period will be ignored. If hardware reset occurs during the programming operation, it is impossible to guarantee the data are being written. Programming is allowed in any sequence and across sector boundaries. Beware that a data "0" cannot be programmed back to a "1" Attempting to do so may either hang up the device or result in an apparent success according to the data polling algorithm but a read from Read/Reset mode will show that the data is still "0" Only erase operations can convert "0"s to "1"s. The Embedded ProgramTM Algorithm using typical command strings and bus operations are illustrated in "(1) Embedded ProgramTM Algorithm" in s FLOW CHART.
Chip Erase
Chip erase is a six bus cycle operation. There are two "unlock" write cycles. These are followed by writing the "set-up" command. Two more "unlock" write cycles are then followed by the chip erase command. Chip erase does not require the user to program the device prior to erase. Upon executing the Embedded Erase Algorithm command sequence the devices will automatically program and verify the entire memory for an all 0 data pattern prior to electrical erase (Preprogram function). The system is not required to provide any controls or timings during these operations. The system can determine the status of the erase operation by using DQ7 (Data Polling), and DQ6 (Toggle Bit). The chip erase begins on the rising edge of the last CE or WE, whichever happens first in the command sequence and terminates when the data on DQ7 is "1" (See "Write Operation Status" section.) at which time the device returns to read the mode. Chip Erase Time; Sector Erase Time x All sectors + Chip Program Time (Preprogramming) The Embedded EraseTM Algorithm using typical command strings and bus operations are illustrated in "(2) Embedded EraseTM Algorithm" in s FLOW CHART.
Sector Erase
Sector erase is a six bus cycle operation. There are two "unlock" write cycles. These are followed by writing the "set-up" command. Two more "unlock" write cycles are then followed by the Sector Erase command. The sector address (any address location within the desired sector) is latched on the falling edge of CE or WE whichever happens later, while the command (Data = 30h) is latched on the rising edge of CE or WE which happens first. After time-out of "tTOW" from the rising edge of the last sector erase command, the sector erase operation will begin.
21
MBM29LV650UE90/651UE90
Multiple sectors may be erased concurrently by writing the six bus cycle operations on "MBM29LV650UE/651UE Command Definitions Table" in s DEVICE BUS OPERATION. This sequence is followed with writes of the Sector Erase command to addresses in other sectors desired to be concurrently erased. The time between writes must be less than "tTOW" otherwise that command will not be accepted and erasure will start. It is recommended that processor interrupts be disabled during this time to guarantee this condition. The interrupts can be re-enabled after the last Sector Erase command is written. A time-out of "tTOW" from the rising edge of last CE or WE whichever happens first will initiate the execution of the Sector Erase command(s). If another falling edge of CE or WE, whichever happens first occurs within the "tTOW" time-out window the timer is reset. (Monitor DQ3 to determine if the sector erase timer window is still open, see section "DQ3", Sector Erase Timer.) Any command other than Sector Erase or Erase Suspend during this time-out period will reset the devices to the read mode, ignoring the previous command string. Resetting the devices once execution has begun will corrupt the data in the sector. In that case, restart the erase on those sectors and allow them to complete. (Refer to "Write Operation Status" section for Sector Erase Timer operation.) Loading the sector erase buffer may be done in any sequence and with any number of sectors (0 to 127). Sector erase does not require the user to program the devices prior to erase. The devices automatically program all memory locations in the sector(s) to be erased prior to electrical erase (Preprogram function). When erasing a sector or sectors the remaining unselected sectors are not affected. The system is not required to provide any controls or timings during these operations. The system can determine the status of the erase operation by using DQ7 (Data Polling), and DQ6 (Toggle Bit). The sector erase begins after the "tTOW" time out from the rising edge of CE or WE whichever happens first for the last sector erase command pulse and terminates when the data on DQ7 is "1" (See "Write Operation Status" section.) at which time the devices return to the read mode. Data polling and Toggle Bit must be performed at an address within any of the sectors being erased. Multiple Sector Erase Time = [Sector Erase Time + Sector Program Time (Preprogramming)] x Number of Sector Erase The Embedded EraseTM Algorithm using typical command strings and bus operations are illustrated "(2) Embedded EraseTM Algorithm" in s FLOW CHART.
Erase Suspend/Resume
The Erase Suspend command allows the user to interrupt a Sector Erase operation and then perform data reads from or programs to a sector not being erased. This command is applicable ONLY during the Sector Erase operation which includes the time-out period for sector erase. The Erase Suspend command will be ignored if written during the Chip Erase operation or Embedded Program Algorithm. Writting the Erase Suspend command (B0h) during the Sector Erase time-out results in immediate termination of the time-out period and suspension of the erase operation. Writing the Erase Resume command (30h) resumes the erase operation. The addresses are "Don't Care" when writting the Erase Suspend or Erase Resume command. When the Erase Suspend command is written during the Sector Erase operation, the device will take a maximum of "tSPD" to suspend the erase operation. When the devices have entered the erase-suspended mode, the DQ7 bit will be at logic "1" and DQ6 will stop toggling. The user must use the address of the erasing sector for reading DQ6 and DQ7 to determine if the erase operation has been suspended. Further writes of the Erase Suspend command are ignored. When the erase operation has been suspended, the devices default to the erase-suspend-read mode. Reading data in this mode is the same as reading from the standard read mode except that the data must be read from sectors that have not been erase-suspended. Successively reading from the erase-suspended sector while the device is in the erase-suspend-read mode will cause DQ2 to toggle. (See the section on "DQ2".)
22
MBM29LV650UE90/651UE90
After entering the erase-suspend-read mode, the user can program the device by writing the appropriate command sequence for Program. This program mode is known as the erase-suspend-program mode. Again, programming in this mode is the same as programming in the regular Program mode except that the data must be programmed to sectors that are not erase-suspended. Successively reading from the erase-suspended sector while the devices are in the erase-suspend-program mode will cause DQ2 to toggle. The end of the erasesuspended Program operation is detected by the Data polling of DQ7 or by the Toggle Bit I (DQ6) which is the same as the regular Program operation. Note that DQ7 must be read from the Program address while DQ6 can be read from any address. To resume the operation of Sector Erase, the Resume command (30h) should be written. Any further writes of the Resume command at this point will be ignored. Another Erase Suspend command can be written after the chip has resumed erasing.
Extended Command
(1) Fast Mode MBM29LV650UE/651UE have Fast Mode function. This mode dispenses with the initial two unclock cycles required in the standard program command sequence by writing Fast Mode command into the command register. In this mode, the required bus cycle for programming is two cycles instead of four bus cycles in standard program command. (Do not write erase command in this mode.) The read operation is also executed after exiting this mode. To exit this mode, it is necessary to write Fast Mode Reset command into the command register. (Refer to "(7) Extended Sector Group Protection Algorithm" in s FLOW CHART.) The VCC active current is required even CE = VIH during Fast Mode. (2) Fast Programming During Fast Mode, the programming can be executed with two bus cycles operation. The Embedded Program Algorithm is executed by writing program set-up command (A0h) and data write cycles (PA/PD). (Refer to "(7) Extended Sector Group Protection Algorithm" in s FLOW CHART.) (3) Extended Sector Group Protection In addition to normal sector group protection, the MBM29LV650UE/651UE have Extended Sector Group Protection as extended function. This function enables to protect sector group by forcing VID on RESET pin and write a command sequence. Unlike conventional procedure, it is not necessary to force VID and control timing for control pins. The only RESET pin requires VID for sector group protection in this mode. The extended sector group protection requires VID on RESET pin. With this condition, the operation is initiated by writing the set-up command (60h) into the command register. Then, the sector group addresses pins (A21, A20, A19, A18, and A17) and (A6, A1, A0) = (0, 1, 0) should be set to the sector group to be protected (recommend to set VIL for the other addresses pins), and write extended sector group protection command (60h). A sector group is typically protected in 250 s. To verify programming of the protection circuitry, the sector group addresses pins (A21, A20, A19, A18, and A17) and (A6, A1, A0) = (0, 1, 0) should be set and write a command (40h). Following the command write, a logic "1" at device output DQ0 will produce for protected sector in the read operation. If the output data is logical "0", please repeat to write extended sector group protection command (60h) again. To terminate the operation, it is necessary to set RESET pin to VIH. (Refer to "(11) Extended Sector Group Protection Timing Diagram" in s TIMING DIAGRAM and "(8) Embedded ProgramTM Algorithm for Fast Mode" in s FLOW CHART.) (4) CFI (Common Flash Memory Interface) The CFI (Common Flash Memory Interface) specification outlines device and host system software interrogation handshake which allows specific vendor-specified software algorithms to be used for entire families of devices. This allows device-independent, JEDEC ID-independent, and forward-and backward-compatible software support for the specified flash device families. Refer to CFI specification in detail. The operation is initiated by writing the query command (98h) into the command register. Following the command write, a read cycle from specific address retrieves device information. Please note that output data of upper byte (DQ8 to DQ15) is "0" in word mode (16 bit) read. To terminate operation, it is necessary to write the read/reset command sequence into the register. (See "Common Flash Memory Interface Code Table" in s FLEXIBLE SECTOR-ERASE ARCHITECTURE.) 23
MBM29LV650UE90/651UE90
HiddenROM Region
The HiddenROM feature provides a Flash memory region that the system may access through a new command sequence. This is primarily intended for customers who wish to use an Electronic Serial Number (ESN) in the device with the ESN protected against modification. Once the HiddenROM region is programmed, any further modification of that region is impossible. This ensures the security of the ESN once the product is shipped to the field. The HiddenROM region is 128 words in length. After the system writes the Enter HiddenROM command sequence, it may read the HiddenROM region by using device addresses A0 to A6 (A7 to A14 are "00", A15 to A21 are don't care). That is, the device sends only program command that would normally be sent to the address to the HiddenROM region. This mode of operation continues until the system issues the Exit HiddenROM command sequence, or until power is removed from the device. On power-up, or following a hardware reset, the device reverts to sending commands to the address. If you request Fujitsu to program the ESN in the device, please contact a Fujitsu representative for more information.
Write Operation Status
Detailed in "Hardware Sequence Flags" are all the status flags that can be used to check the status of the device for current mode operation. During sector erase, the part provides the status flags automatically to the I/O ports. The information on DQ2 is address sensitive. This means that if an address from an erasing sector is consecutively read, then the DQ2 bit will toggle. However, DQ2 will not toggle if an address from a non-erasing sector is consecutively read. This allows the user to determine which sectors are erasing and which are not. Once erase suspend is entered, address sensitivity still applies. If the address of a non-erasing sector (that is, one available for read) is provided, then stored data can be read from the device. If the address of an erasing sector (that is, one unavailable for read) is applied, the device will output its status bits. Hardware Sequence Flags Table Status Embedded Program Algorithm Embedded Erase Algorithm Erase Suspend Read (Erase Suspended Sector) Erase Erase Suspend Read Suspended (Non-Erase Suspended Sector) Mode Erase Suspend Program (Non-Erase Suspended Sector) Embedded Program Algorithm Embedded Erase Algorithm Exceeded Time Limits Erase Erase Suspend Program Suspended (Non-Erase Suspended Sector) Mode DQ7 DQ7 0 1 Data DQ7 DQ7 0 DQ7 DQ6 Toggle Toggle 1 Data Toggle Toggle Toggle Toggle DQ5 0 0 0 Data 0 1 1 1 DQ3 0 1 0 Data 0 0 1 0 DQ2 1 Toggle* Toggle Data 1* 1 N/A N/A
In Progress
*: Successive reads from the erasing or erase-suspend sector causes DQ2 to toggle. Reading from non-erase suspend sector address will indicate logic "1" at the DQ2 bit.
24
MBM29LV650UE90/651UE90
DQ7 Data Polling
The MBM29LV650UE/651UE devices feature Data Polling as a method to indicate to the host that the Embedded Algorithms are in progress or completed. During the Embedded Program Algorithm an attempt to read the devices produce reverse data last written to DQ7. Upon completion of the Embedded Program Algorithm, an attempt to read the device will produce the true data last written to DQ7. During the Embedded Erase Algorithm, an attempt to read the device will produce a "0" at the DQ7 output. Upon completion of the Embedded Erase Algorithm an attempt to read the device will produce a "1" at the DQ7 output. The flowchart for Data Polling (DQ7) is shown in "(3) Data Polling Algorithm" in s FLOW CHART. For programming, the Data Polling is valid after the rising edge of fourth write pulse in the four write pulse sequence. For chip erase and sector erase, the Data Polling is valid after the rising edge of the sixth write pulse in the six write pulse sequence. Data Polling must be performed at sector address within any of the sectors being erased and not a protected sector. Otherwise, the status may not be valid. Once the Embedded Algorithm operation is close to being completed, the MBM29LV650UE/651UE data pins (DQ7) may change asynchronously while the output enable (OE) is asserted low. This means that the devices are driving status information on DQ7 at one instant of time and then that byte's valid data at the next instant of time. Depending on when the system samples the DQ7 output, it may read the status or valid data. Even if the device has completed the Embedded Algorithm operation and DQ7 has a valid data, the data outputs on DQ0 to DQ6 may be still invalid. The valid data on DQ0 to DQ7 will be read on the successive read attempts. The Data Polling feature is only active during the Embedded Programming Algorithm, Embedded Erase Algorithm or sector erase time-out. (See "Hardware Sequence Flags".) See "(6) Data Polling during Embedded Algorithm Operation Timing Diagram" in s TIMING DIAGRAM for the Data Polling timing specifications and diagram.
DQ6 Toggle Bit I
The MBM29LV650UE/651UE also feature the "Toggle Bit I" as a method to indicate to the host system that the Embedded Algorithms are in progress or completed. During an Embedded Program or Erase Algorithm cycle, successive attempts to read (CE or OE toggling) data from the devices will result in DQ6 toggling between 1 and 0. Once the Embedded Program or Erase Algorithm cycle is completed, DQ6 will stop toggling and valid data will be read on the next successive attempts. During programming, the Toggle Bit I is valid after the rising edge of the fourth write pulse in the four write pulse sequence. For chip erase and sector erase, the Toggle Bit I is valid after the rising edge of the sixth write pulse in the six write pulse sequence. The Toggle Bit I is active during the sector time out. In programming, if the sector being written to is protected, the toggle bit will toggle for about 1 s and then stop toggling without the data having changed. In erase, the devices will erase all the selected sectors except for the ones that are protected. If all selected sectors are protected, the chip will toggle the toggle bit for about 400 s and then drop back into read mode, having changed none of the data. Either CE or OE toggling will cause the DQ6 to toggle. In addition, an Erase Suspend/Resume command will cause the DQ6 to toggle. See "(7) Toggle Bit I during Embedded Algorithm Operation Timing Diagram" in s TIMING DIAGRAM for the Toggle Bit I timing specifications and diagram.
25
MBM29LV650UE90/651UE90
DQ5 Exceeded Timing Limits
DQ5 will indicate if the program or erase time has exceeded the specified limits (internal pulse count). Under these conditions DQ5 will produce a "1". This is a failure condition which indicates that the program or erase cycle was not successfully completed. Data Polling is the only operating function of the devices under this condition. The CE circuit will partially power down the device under these conditions (to approximately 2 mA). The OE and WE pins will control the output disable functions as described in "MBM29LV650UE/651UE User Bus Operations Table" in s DEVICE BUS OPERATION. The DQ5 failure condition may also appear if a user tries to program a non blank location without erasing. In this case the devices lock out and never complete the Embedded Algorithm operation. Hence, the system never reads a valid data on DQ7 bit and DQ6 never stops toggling. Once the devices have exceeded timing limits, the DQ5 bit will indicate a "1". Please note that this is not a device failure condition since the devices were incorrectly used. If this occurs, reset the device with command sequence.
DQ3 Sector Erase Timer
After the completion of the initial sector erase command sequence the sector erase time-out will begin. DQ3 will remain low until the time-out is complete. Data Polling and Toggle Bit are valid after the initial sector erase command sequence. If Data Polling or the Toggle Bit I indicates the device has been written with a valid erase command, DQ3 may be used to determine if the sector erase timer window is still open. If DQ3 is high ("1") the internally controlled erase cycle has begun; attempts to write subsequent commands to the device will be ignored until the erase operation is completed as indicated by Data Polling or Toggle Bit I. If DQ3 is low ("0"), the device will accept additional sector erase commands. To insure the command has been accepted, the system software should check the status of DQ3 prior to and following each subsequent Sector Erase command. If DQ3 were high on the second status check, the command may not have been accepted. See "Hardware Sequence Flags Table".
DQ2 Toggle Bit II
This toggle bit II, along with DQ6, can be used to determine whether the devices are in the Embedded Erase Algorithm or in Erase Suspend. Successive reads from the erasing sector will cause DQ2 to toggle during the Embedded Erase Algorithm. If the devices are in the erase-suspended-read mode, successive reads from the erase-suspended sector will cause DQ2 to toggle. When the devices are in the erase-suspended-program mode, successive reads from the byte address of the non-erase suspended sector will indicate a logic "1" at the DQ2 bit. DQ6 is different from DQ2 in that DQ6 toggles only when the standard program or Erase, or Erase Suspend Program operation is in progress (see"Hardware Sequences Flags"). The behavior of these two status bits, along with that of DQ7, is summarized as follows: For example, DQ2 and DQ6 can be used together to determine if the erase-suspend-read mode is in progress. (DQ2 toggles while DQ6 does not.) Furthermore, DQ2 can also be used to determine which sector is being erased. When the device is in the erase mode, DQ2 toggles if this bit is read from an erasing sector.
26
MBM29LV650UE90/651UE90
Toggle Bit Status Table Mode Program Erase Erase-Suspend Read (Erase-Suspended Sector) Erase-Suspend Program DQ7 DQ7 0 1 DQ7 DQ6 Toggle Toggle 1 Toggle DQ2 1 Toggle * Toggle 1*
*: Successive reads from the erasing or erase-suspend sector will cause DQ2 to toggle. Reading from non-erase suspend sector address will indicate logic "1" at the DQ2 bit.
Data Protection
The MBM29LV650UE/651UE is designed to offer protection against accidental erasure or programming caused by spurious system level signals that may exist during power transitions. During power up the devices automatically reset the internal state machine in the Read mode. Also, with its control register architecture, alteration of the memory contents only occurs after successful completion of specific multi-bus cycle command sequences. The devices also incorporate several features to prevent inadvertent write cycles resulting form VCC power-up and power-down transitions or system noise.
Low VCC Write Inhibit
To avoid initiation of a write cycle during VCC power-up and power-down, a write cycle is locked out for VCC less than VLKO (Min). If VCC < VLKO, the command register is disabled and all internal program/erase circuits are disabled. Under this condition the device will reset to the read mode. Subsequent writes will be ignored until the VCC level is greater than VLKO. It is the users responsibility to ensure that the control pins are logically correct to prevent unintentional writes when VCC is above VLKO (Min). If Embedded Erase Algorithm is interrupted, there is possibility that the erasing sector(s) cannot be used.
Write Pulse "Glitch" Protection
Noise pulses of less than 3 ns (typical) on OE, CE, or WE do not initiate write cycle.
Logical Inhibit
Writing is inhibited by holding any one of OE = VIL, CE = VIH, or WE = VIH. To initiate a write, CE and WE must be a logic 0 while OE is a logic 1.
Power-up Write Inhibit
Power-up of the devices with WE = CE = VIL and OE = VIH will not accept commands on the rising edge of WE. The internal state machine is automatically reset to read mode on power-up. Sector Group Protection Device user is able to protect each sector group individually to store and protect data. Protection circuit voids both program and erase commands that are addressed to protected sectors. Any commands to program or erase addressed to protected sector are ignored (see "Sector Group Protection" in s FUNCTIONAL DESCRIPTION).
27
MBM29LV650UE90/651UE90
s ABSOLUTE MAXIMUM RATINGS
Parameter Storage Temperature Ambient Temperature with Power Applied Voltage with respect to Ground All Pins Except A9, OE, ACC, and RESET*1, *2 Power Supply Voltage*1 A9, OE, ACC, and RESET*1, *3 Power Supply Voltage*
1
Symbol Tstg TA VIN, VOUT VCC VIN Vccq
Rating Min -55 -40 -0.5 -0.5 -0.5 -0.2 Max +125 +85 VCC +0.5 +4.0 +13.0 +7.0
Unit C C V V V V
*1 : Voltage is defined on the basis of VSS = GND = 0 V. *2 : Minimum DC voltage on input or I/O pins is -0.5 V. During voltage transitions, input or I/O pins may undershoot VSS to -2.0 V for periods of up to 20 ns. Maximum DC voltage on input or I/O pins is VCC +0.5 V. During voltage transitions, input or I/O pins may overshoot to VCC + 2.0 V for periods of up to 20 ns. *3: Minimum DC input voltage on A9, OE, ACC and RESET pins is -0.5 V. During voltage transitions, A9, OE, ACC and RESET pins may undershoot VSS to -2.0 V for periods of up to 20 ns. Voltage difference between input and supply voltage on (VIN - VCC) dose not exceed +9.0 V. Maximum DC input voltage on A9, OE, ACC and RESET pins is +13.0 V which may overshoot to +14.0 V for periods of up to 20 ns. WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current, temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
s RECOMMENDED OPERATING CONDITIONS
Parameter Ambient Temperature Power Supply Voltage (VCC)* Power Supply Voltage (Vccq)* Symbol TA VCC Vccq Value Min -40 +3.0 +3.0 Max +85 +3.6 +3.6 Unit C V V
*: Voltage is defined on the basis of VSS = GND = 0 V. WARNING: The recommended operating conditions are required in order to ensure the normal operation of the semiconductor device. All of the device's electrical characteristics are warranted when the device is operated within these ranges. Always use semiconductor devices within their recommended operating condition ranges. Operation outside these ranges may adversely affect reliability and could result in device failure. No warranty is made with respect to uses , operating conditions, or combinations not represented on the data sheet. Users considering application outside the listed conditions are advised to contact their FUJITSU representatives beforehand.
28
MBM29LV650UE90/651UE90
s MAXIMUM OVERSHOOT/MAXIMUM UNDERSHOOT
+0.6 V -0.5 V -2.0 V
20 ns
20 ns
20 ns
Maximum Undershoot Waveform
20 ns
VCC +2.0 V VCC +0.5 V +2.0 V
20 ns 20 ns
Maximum Overshoot Waveform 1
20 ns
+14.0 V +13.0 V VCC +0.5 V
20 ns 20 ns
Note: This waveform is applied for A9, OE, ACC, and RESET. Maximum Overshoot Waveform 2
29
MBM29LV650UE90/651UE90
s DC CHARACTERISTICS
Parameter Input Leakage Current Output Leakage Current A9, OE, RESET Inputs Leakage Current Symbol ILI ILO ILIT Conditions VIN = VSS to VCC, VCC = VCC Max, VCCq = VCCq Max VOUT = VSS to VCC, VCC = VCC Max, VCCq = VCCq Max VCC = VCC Max, A9, OE, RESET = 12.5 V CE = VIL, OE = VIH, VCC = VCC Max, VCCq = VCCq Max, f = 5 MHz CE = VIL, OE = VIH, VCC = VCC Max, VCCq = VCCq Max, f = 1 MHz CE = VIL, OE = VIH, VCC = VCC Max, VCCq = VCCq Max VCC = VCC Max, VCCq = VCCq Max, CE = VCC 0.3 V, RESET = VCC 0.3 V VCC = VCC Max, VCCq = VCCq Max, RESET = VSS 0.3 V VCC = VCC Max, VCCq = VCCq Max, CE = VSS 0.3 V, RESET = VCC 0.3 V, VIN = VCC 0.3 V or VSS 0.3 V VCC = VCC Max, ACC = VACC Max -- -- -- -- IOL = 4.0 mA, VCC = VCC Min, VCCq = VCCq Min IOH = -2.0 mA, VCC = VCC Min, VCCq = VCCq Min IOH = -100 A, VCC Min, VCCq = VCCq Min -- Value Min -1.0 -1.0 -- -- -- -- -- -- Max +1.0 +1.0 35 16 7 40 5 5 Unit A A A mA mA mA A A
VCC Active Current *1
ICC1
VCC Active Current*2 VCC Current (Standby) VCC Current (Standby, RESET) VCC Current (Automatic Sleep Mode) *5 ACC Accelerated Program Current Input Low Voltage Input High Voltage Voltage for Program Acceleration Voltage for Autoselect, Sector Protection (A9, OE, RESET) *3, *4 Output Low Voltage
ICC2 ICC3 ICC4
ICC5
--
5
A
IACC VIL VIH VACC VID VOL VOH1
-- -0.5 2.0 11.5 11.5 -- 2.4 VCCq - 0.4 2.3
20 0.6 VCC + 0.5 12.5 12.5 0.45 -- -- 2.5
mA V V V V V V V V
Output High Voltage VOH2 Low VCC Lock-Out Voltage VLKO
*1 : The lCC current listed includes both the DC operating current and the frequency dependent component. *2 : lCC active while Embedded Erase or Embedded Program is in progress. *3 : This timing is only for Sector Group Protection Operation. *4 : Applicable for only VCC applying. *5 : Automatic sleep mode enables the low power mode when address remains stable for 150 ns.
30
MBM29LV650UE90/651UE90
s AC CHARACTERISTICS
* Read Only Operations Characteristics Parameter Read Cycle Time Address to Output Delay Chip Enable to Output Delay Output Enable to Output Delay Chip Enable to Output High-Z Output Enable to Output High-Z Output Hold Time From Address, CE or OE, Whichever Occurs First RESET Pin Low to Read Mode Symbol JEDEC tAVAV tAVQV tELQV tGLQV tEHQZ tGHQZ tAXQX -- Standard tRC tACC tCE tOE tDF tDF tOH tREADY Test Setup -- CE = VIL OE = VIL OE = VIL -- -- -- -- -- Value* Min 90 -- -- -- -- -- 0 -- Max -- 90 90 35 30 30 -- 20 Unit ns ns ns ns ns ns ns s
* : Test Conditions : Output Load : 1 TTL gate and 30 pF (MBM29LV650UE/651UE90) Input rise and fall times : 5 ns Input pulse levels : 0.0 V or 3.0 V Timing measurement reference level Input : 1.5 V Output : 1.5 V
3.3 V IN3064 or Equivalent Device Under Test 6.2 k CL Diodes = IN3064 or Equivalent
2.7 k
Note : CL = 30 pF including jig capacitance Test Conditions
31
MBM29LV650UE90/651UE90
* Write (Erase/Program) Operations Parameter Write Cycle Time Address Setup Time Address Hold Time Data Setup Time Data Hold Time Output Enable Setup Time Output Enable Hold Time Read Toggle and Data Polling Symbols JEDEC tAVAV tAVWL tWLAX tDVWH tWHDX -- -- tGHWL tGHEL tELWL tWLEL tWHEH tEHWH tWLWH tELEH tWHWL tEHEL tWHWH1
1
Value Min 90 0 45 35 0 0 0 10 0 0 0 0 0 0 35 35 30 30 50 500 500 4 100 4 4 500 200 50 Typ 16 1 Max 90 20
Standard tWC tAS tAH tDS tDH tOES tOEH tGHWL tGHEL tCS tWS tCH tWH tWP tCP tWPH tCPH tWHWH1 tWHWH2 tVCS tVIDR tVACCR tVLHT tWPP tOESP tCSP tRP tRH tEOE tTOW tSPD
Unit ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns s s s ns ns s s s s ns ns ns s s
Read Recover Time Before Write Read Recover Time Before Write CE Setup Time WE Setup Time CE Hold Time WE Hold Time Write Pulse Width CE Pulse Width Write Pulse Width High CE Pulse Width High Programming Operation Sector Erase Operation * VCC Setup Time Rise Time to VID *
2 3 2
tWHWH2 -- -- -- -- -- -- -- -- -- -- -- --
Rise Time to VACC *
Voltage Transition Time * Write Pulse Width *2
OE Setup Time to WE Active *2 CE Setup Time to WE Active *2 RESET Pulse Width RESET High Level Period Before Read Delay Time from Embedded Output Enable Erase Time-out Time Erase Suspend Transition Time *1 : This does not include the preprogramming time.
*2 : This timing is for Sector Group Protection operation. *3 : This timing is for Accelerated Program operation.
32
MBM29LV650UE90/651UE90
s ERASE AND PROGRAMMING PERFORMANCE
Limit Parameter Min Sector Erase Time Programming Time Chip Programming Time Erase/Program Cycle -- -- -- 100,000 Typ 1 16 -- -- Max 10 360 200 -- s s s cycle Excludes programming time prior to erasure Excludes system-level overhead Excludes system-level overhead Unit Comments
s PIN CAPACITANCE
Parameter Input Capacitance Output Capacitance Control Pin Capacitance ACC Pin Capacitance Symbol CIN COUT CIN2 CIN3 Test Setup VIN = 0 VOUT = 0 VIN = 0 VIN = 0 Value Typ 6 8.5 8 15 Max 7.5 12 10 20 Unit pF pF pF pF
Note: Test conditions TA = + 25C, f = 1.0 MHz
33
MBM29LV650UE90/651UE90
s TIMING DIAGRAM
* Key to Switching Waveforms
WAVEFORM
INPUTS Must Be Steady May Change from H to L May Change from L to H "H" or "L" Any Change Permitted Does Not Apply
OUTPUTS Will Be Steady Will Be Changing from H to L Will Be Changing from L to H Changing State Unknown Center Line is HighImpedance "Off" State
(1) Read Operation Timing Diagram
tRC
Address
Address Stable
tACC
CE
tOE tDF
OE
tOEH
WE
tCE tOH
Outputs
High-Z
Output Valid
High-Z
34
MBM29LV650UE90/651UE90
(2) Hardware Reset/Read Operation Timing Diagram
tRC
Address
tACC
Address Stable
CE
tRH
tRP
tRH
tCE
RESET
tOH
Outputs
High-Z
Output Valid
35
MBM29LV650UE90/651UE90
(3) Alternate WE Controlled Program Operation Timing Diagram
3rd Bus Cycle Address
XXXh tWC tAS PA tAH
Data Polling
PA tRC
CE
tCS tCH tCE
OE
tGHWL tWP tWPH tWHWH1 tOE
WE
tDS tDH tDF tOH
Data
A0h
PD
DQ 7
DOUT
DOUT
Notes : * * * * *
PA is address of the memory location to be programmed. PD is data to be programmed at byte address. DQ7 is the output of the complement of the data written to the device. DOUT is the output of the data written to the device. Figure indicates the last two bus cycles out of four bus cycle sequence.
36
MBM29LV650UE90/651UE90
(4) Alternate CE Controlled Program Operation Timing Diagram
3rd Bus Cycle
Data Polling PA tAS tAH PA
Address
XXXh tWC
WE
tWS tWH
OE
tGHEL tCP tCPH tWHWH1
CE
tDS tDH
Data
A0h
PD
DQ 7
DOUT
Notes : * * * * *
PA is address of the memory location to be programmed. PD is data to be programmed at byte address. DQ7 is the output of the complement of the data written to the device. DOUT is the output of the data written to the device. Figure indicates the last the two bus cycles out of four bus cycle sequence.
37
MBM29LV650UE90/651UE90
(5) Chip/Sector Erase Operation Timing Diagram
Address
XXXh tWC
XXXh tAS tAH
XXXh
XXXh
XXXh
SA *
CE
tCS tCH
OE
tGHWL tWP tWPH
WE
tDS AAh
tDH 55h 80h AAh 55h
10h for chip erase 30h
Data
tVCS
VCC
* : SA is the sector address for Sector Erase. Addresses = XXXh for Chip Erase.
38
MBM29LV650UE90/651UE90
(6) Data Polling during Embedded Algorithm Operation Timing Diagram
CE
tCH
tOE
tDF
OE
tOEH
WE
tCE
*
DQ7
Data DQ7 DQ7 = Valid Data
High-Z
tWHWH1 or tWHWH2
DQ0 to DQ6
Data
DQ0 to DQ6 = Output Flag tEOE
DQ0 to DQ6 Valid Data
High-Z
* : DQ7 = Valid Data (The device has completed the Embedded operation.)
(7) Toggle Bit I during Embedded Algorithm Operation Timing Diagram
CE
tOEH
WE
tOES
OE
tDH
*
DQ6 = Toggle DQ6 = Stop Toggling tOE DQ0 to DQ7 Data Valid
DQ6
Data (DQ0 to DQ7)
DQ6 = Toggle
* : DQ6 = Stops toggling. (The device has completed the Embedded operation.)
39
MBM29LV650UE90/651UE90
(8) DQ2 vs. DQ6
Enter Embedded Erasing WE
Erase Suspend Erase
Enter Erase Suspend Program Erase Suspend Program
Erase Resume Erase Suspend Read Erase Erase Complete
Erase Suspend Read
DQ6
DQ2 Toggle DQ2 and DQ6 with OE or CE
Note: DQ2 is read from the erase-suspended sector.
40
MBM29LV650UE90/651UE90
(9) Sector Group Protection Timing Diagram
A21, A20, A19 A18, A17
SPAX
SPAY
A6, A0
A1
12 V 3V A9
tVLHT
12 V 3V OE
tVLHT tWPP tVLHT tVLHT
WE
tOESP
CE
tCSP
Data
tVCS tOE
01h
VCC
SPAX : Sector Group Address to be protected SPAY : Next Sector Group Address to be protected
41
MBM29LV650UE90/651UE90
(10) Temporary Sector Group Unprotection Timing Diagram
VCC tVCS VID VIH RESET CE
tVIDR tVLHT
WE
tVLHT
Program or Erase Command Sequence
tVLHT
Unprotection period
42
MBM29LV650UE90/651UE90
(11) Extended Sector Group Protection Timing Diagram
VCC
tVCS
RESET tVIDR Address A6, A3, A2, A0
tVLHT tWC tWC SPAX SPAX SPAY
A1
CE
OE tWP WE TIME-OUT
Data
60h
60h
40h tOE
01h
60h
SPAX: Sector Group Address to be protected SPAY : Next Sector Group Address to be protected TIME-OUT : Time-Out window = 250 s (Min)
43
MBM29LV650UE90/651UE90
(12) Accelerated Program Timing Diagram
VCC tVCS VACC VIH ACC
tVACCR tVLHT
CE
WE tVLHT Program Command Sequence tVLHT
Acceleration period
44
MBM29LV650UE90/651UE90
s FLOW CHART
1. Embedded ProgramTM Algorithm
EMBEDDED ALGORITHMS
Start
Write Program Command Sequence (See below)
Data Polling
No
Verify Data
? Yes
Embeded Program Algorithm in progress
Increment Address
No
Last Address ? Yes
Programming Completed Program Command Sequence (Address/Command):
XXXh/AAh
XXXh/55h
XXXh/A0h
Program Address/Program Data
45
MBM29LV650UE90/651UE90
2. Embedded EraseTM Algorithm
EMBEDDED ALGORITHMS
Start
Write Erase Command Sequence (See below)
Data Polling
No
Data=FFh ? Yes Erasure Completed
Embeded Program Algorithm in progress
Chip Erase Command Sequence (Address/Command): XXXh/AAh
Individual Sector/Multiple Sector Erase Command Sequence (Address/Command): XXXh/AAh
XXXh/55h
XXXh/55h
XXXh/80h
XXXh/80h
XXXh/AAh
XXXh/AAh
XXXh/55h
XXXh/55h
XXXh/10h
Sector Address/30h
Sector Address/30h
Additional sector erase commands are optional.
Sector Address/30h
46
MBM29LV650UE90/651UE90
3. Data Polling Algorithm
Start
Read Byte (DQ 7 to DQ 0) Addr. = VA
DQ 7 = Data? No No DQ 5 = 1? Yes Read Byte (DQ 7 to DQ 0) Addr. = VA
Yes
VA = Byte address for programming = Any of the sector addresses within the sector being erased during sector erase or multiple sector erases operation = Any of the sector addresses within the sector not being protected during chip erase
DQ 7 = Data? * No Fail
Yes
Pass
* : DQ7 is rechecked even if DQ5 = "1" because DQ7 may change simultaneously with DQ5.
47
MBM29LV650UE90/651UE90
4. Toggle Bit Algorithm
Start
Read (DQ 7 to DQ 0 ) Addr. = "H" or "L" *1 Read (DQ 7 to DQ 0 ) Addr. = "H" or "L" DQ 6 = Toggle ? Yes No DQ 5 = 1? Yes *1,*2 Read DQ 7 to DQ 0 Twice Addr. = "H" or "L"
No
DQ 6 = Toggle ? Yes Program/Erase Operation Not Complete.Write Reset Command
No
Program/Erase Operation Complete
*1:Reset toggle bit twice to determine whether it is toggling. *2:Recheck toggle bit because it may stop toggling as DQ5 changes to "1" .
48
MBM29LV650UE90/651UE90
5. Sector Group Protection Algorithm
Start
Setup Sector Group Addr. (A21, A20, A19, A18, A17)
PLSCNT = 1
OE = V ID, A 9 = V ID, CE = V IL, RESET = V IH A 6 = A 0 = V IL, A 1 = V IH Activate WE Pulse
Increment PLSCNT
Time out 100 s
WE = V IH, CE = OE = V IL (A 9 should remain V ID)
Read from Sector Group (Addr. = SPA, A 1 = V IH, A 6 = A 0 = V IL) No No PLSCNT = 25? Yes Remove V ID from A 9 Write Reset Command Data = 01h? Yes Yes Protect Another Sector Group ? No Remove V ID from A 9 Write Reset Command
Device Failed
Sector Group Protection Completed
49
MBM29LV650UE90/651UE90
6. Temporary Sector Group Unprotection Algorithm
Start
RESET = VID *1
Perform Erase or Program Operations
RESET = VIH
Temporary Sector Group Unprotection Completed *2
*1: All protected sector groups are unprotected. *2: All previously protected sector groups are protected once again.
50
MBM29LV650UE90/651UE90
7. Extended Sector Group Protection Algorithm
Start
RESET = VID
Wait to 4 s
Device is Operating in Temporary Sector Group Unprotection Mode
No
Extended Sector Group Protection Entry? Yes To Setup Sector Group Protection Write XXXh/60h
PLSCNT = 1 To Sector Group Protection Write SPA/60h (A6 = A0 = VIL, Addr. = SPA, A1 = VIH) Increment PLSCNT Time Out 250 s Setup Next Sector Group Address
To Verify Sector Group Protection Write SPA/40h (A6 = A0 = VIL, A1 = VIH) Read from Sector Group Address (A6 = A0 = VIL, Addr. = SPA, A1 = VIH) No PLSCNT = 25? Yes Remove VID from RESET Write Reset Command No Data = 01h? Yes Protection Other Sector Group? No Device Failed Remove VID from RESET Write Reset Command
Yes
Sector Group Protection Completed
51
MBM29LV650UE90/651UE90
8. Embedded ProgramTM Algorithm for Fast Mode
FAST MODE ALGORITHM
Start
XXXh/AAh
XXXh/55h
Set Fast Mode
XXXh/20h
XXXh/A0h
Program Address/Program Data
Data Polling Device
Verify Data? Yes No
No
In Fast Program
Increment Address
Last Address ? Yes Programming Completed
XXXh/90h Reset Fast Mode XXXh/F0h
52
MBM29LV650UE90/651UE90
s ORDERING INFORMATION
MBM29LV650U(651U) E 90 TN
PACKAGE TYPE TN= 48-Pin Thin Small Outline Package (TSOP) Normal Bend TR = 48-Pin Thin Small Outline Package (TSOP) Reverse Bend
SPEED OPTION See Product Selector Guide
DEVICE REVISION
DEVICE NUMBER/DESCRIPTION MBM29LV650U(651U) 64 Mega-bit (4M x 16-Bit) 3.0 V-only Read, Program and Erase
Part No. MBM29LV650UE90TN
Package 48-pin plastic TSOP (1) (FPT-48P-M19) Normal Bend 48-pin plastic TSOP (1) (FPT-48P-M20) Reverse Bend 48-pin plastic TSOP (1) (FPT-48P-M19) Normal Bend 48-pin plastic TSOP (1) (FPT-48P-M20) Reverse Bend
Access Time (ns) 90
Remarks
Hardware protection with WP = SA127 90
MBM29LV650UE90TR
MBM29LV651UE90TN
90 Hardware protection with WP = SA0 90
MBM29LV651UE90TR
53
MBM29LV650UE90/651UE90
s PACKAGE DIMENSIONS
48-pin plastic TSOP (1) (FPT-48P-M19)
Note 1) * : Values do not include resin protrusion. Resin protrusion and gate protrusion are +0.15(.006)Max(each side). Note 2) Pins width and pins thickness include plating thickness. Note 3)Pins width do not include tie bar cutting remainder.
LEAD No.
1 48
INDEX
Details of "A" part
0.25(.010)
0~8
0.600.15 (.024.006)
24
25
20.000.20 (.787.008) * 18.400.20 (.724.008)
* 12.000.20
(.472.008) 1.10 -0.05
+0.10 +.004
.043 -.002 (Mounting height)
0.50(.020)
"A"
0.10(.004)
0.17 -0.08 .007 -.003
C
+0.03 +.001
0.100.05 (.004.002) (Stand off height) 0.220.05 (.009.002) 0.10(.004)
M
2003 FUJITSU LIMITED F48029S-c-6-7
Dimensions in mm (inches)
(Continued)
54
MBM29LV650UE90/651UE90
(Continued)
48-pin plastic TSOP (1) (FPT-48P-M20)
Note 1) * : Values do not include resin protrusion. Resin protrusion and gate protrusion are +0.15(.006)Max(each side). Note 2) Pins width and pins thickness include plating thickness. Note 3) Pins width do not include tie bar cutting remainder.
LEAD No.
1 48
INDEX
Details of "A" part 0.600.15 (.024.006)
0~8 0.25(.010)
24
25
0.17 -0.08
+0.03 +.001
0.10(.004)
.007 -.003 0.50(.020)
0.220.05 (.009.002)
0.10(.004)
M
0.100.05 (.004.002) (Stand off height)
"A"
1.10 -0.05
+0.10 +.004
* 18.400.20
(.724.008) 20.000.20 (.787.008)
.043 -.002 (Mounting height)
* 12.000.20(.472.008)
C
2003 FUJITSU LIMITED F48030S-c-6-7
Dimensions in mm (inches)
(Continued)
55
MBM29LV650UE90/651UE90
FUJITSU LIMITED
All Rights Reserved. The contents of this document are subject to change without notice. Customers are advised to consult with FUJITSU sales representatives before ordering. The information, such as descriptions of function and application circuit examples, in this document are presented solely for the purpose of reference to show examples of operations and uses of Fujitsu semiconductor device; Fujitsu does not warrant proper operation of the device with respect to use based on such information. When you develop equipment incorporating the device based on such information, you must assume any responsibility arising out of such use of the information. Fujitsu assumes no liability for any damages whatsoever arising out of the use of the information. Any information in this document, including descriptions of function and schematic diagrams, shall not be construed as license of the use or exercise of any intellectual property right, such as patent right or copyright, or any other right of Fujitsu or any third party or does Fujitsu warrant non-infringement of any third-party's intellectual property right or other right by using such information. Fujitsu assumes no liability for any infringement of the intellectual property rights or other rights of third parties which would result from the use of information contained herein. The products described in this document are designed, developed and manufactured as contemplated for general use, including without limitation, ordinary industrial use, general office use, personal use, and household use, but are not designed, developed and manufactured as contemplated (1) for use accompanying fatal risks or dangers that, unless extremely high safety is secured, could have a serious effect to the public, and could lead directly to death, personal injury, severe physical damage or other loss (i.e., nuclear reaction control in nuclear facility, aircraft flight control, air traffic control, mass transport control, medical life support system, missile launch control in weapon system), or (2) for use requiring extremely high reliability (i.e., submersible repeater and artificial satellite). Please note that Fujitsu will not be liable against you and/or any third party for any claims or damages arising in connection with above-mentioned uses of the products. Any semiconductor devices have an inherent chance of failure. You must protect against injury, damage or loss from such failures by incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels and other abnormal operating conditions. If any products described in this document represent goods or technologies subject to certain restrictions on export under the Foreign Exchange and Foreign Trade Law of Japan, the prior authorization by Japanese government will be required for export of those products from Japan.
F0303 (c) FUJITSU LIMITED Printed in Japan


▲Up To Search▲   

 
Price & Availability of MBM29LV650UE90

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X