Part Number Hot Search : 
MM1025 F1205 LM7905AG LM7905AG CJSE074 SC6200 RD12V K4212
Product Description
Full Text Search
  convection conduction Datasheet PDF File

For convection conduction Found Datasheets File :: 1709    Search Time::2.719ms    
Page :: | 1 | 2 | 3 | 4 | <5> | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |   

    RPT-75 RPT-7503 RPT-75A RPT-75B RPT-75C RPT-75D

Mean Well Enterprises Co., Ltd.
Part No. RPT-75 RPT-7503 RPT-75A RPT-75B RPT-75C RPT-75D
OCR Text ...verload / Over voltage Free air convection for rated power and 23.5CFM forced air convection for peak load UL60601-1/IEC60601-1/EN60601-1 me...conduction & RADIATION Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B Compliance to EN61...
Description 75W Triple Output Medical Type

File Size 524.20K  /  3 Page

View it Online

Download Datasheet





    CR08AS

MITSUBISHI[Mitsubishi Electric Semiconductor]
Part No. CR08AS
OCR Text ...ISTIVE, INDUCTIVE LOADS NATURAL convection 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 AVERAGE ON-STATE CURRENT (A) AVERAGE ON-STATE CURRENT (A) Feb.1999 MITSUBISHI SEMICONDUCTOR THYRISTOR CR08AS LOW POWER USE NON-INSULATED TYPE, GL...
Description LOW POWER USE NON-INSULATED TYPE/ GLASS PASSIVATION TYPE
LOW POWER USE NON-INSULATED TYPE, GLASS PASSIVATION TYPE

File Size 72.45K  /  6 Page

View it Online

Download Datasheet

    PQ-100 PQ-100C PQ-100B

Mean Well Enterprises Co., Ltd.
Part No. PQ-100 PQ-100C PQ-100B
OCR Text ...ver voltage Cooling by free air convection With power good signal output(Optional) 100% full load burn-in test Fixed switching frequency at ...conduction & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN6100...
Description 100W Quad Output Switching Power Supply

File Size 662.80K  /  3 Page

View it Online

Download Datasheet

    PS-45-12 PS-65-3.3 PS-25-13.5 PS-25-7.5 PS-25-24 PS-25-48 PS-45-7.5 PS-45-24 PS-45-27 PS-45-3.3 PS-25-27 PS-45-48 PS-45-

XP Power Limited
Part No. PS-45-12 PS-65-3.3 PS-25-13.5 PS-25-7.5 PS-25-24 PS-25-48 PS-45-7.5 PS-45-24 PS-45-27 PS-45-3.3 PS-25-27 PS-45-48 PS-45-13.5 PS-25-12 PS-45-5 PS-45-15 PS-25-15
OCR Text ...temperature Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 100KHz Low cost High reliability 2 years...conduction & RADIATION (Note 4) HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS NOTE PS-25-3.3 3.3V 5A...
Description 25W Single Output Switching Power Supply

File Size 1,086.01K  /  6 Page

View it Online

Download Datasheet

    CR02AM-4 CR02AM CR02AM-6 CR02AM-8

MITSUBISHI[Mitsubishi Electric Semiconductor]
Mitsubishi Electric Corporation
Part No. CR02AM-4 CR02AM CR02AM-6 CR02AM-8
OCR Text ...ISTIVE, INDUCTIVE LOADS NATURAL convection 180 0.3 0.4 360 RESISTIVE LOADS 0.5 0.3 0.4 AVERAGE ON-STATE CURRENT (A) AVERAGE ON-STATE CURRENT (A) AVERAGE POWER DISSIPATION (W) ALLOWABLE AMBIENT TEMPERATURE VS. AVERAGE ON-ST...
Description 0.47 A, 200 V, SCR, TO-92
0.47 A, 300 V, SCR, TO-92
LOW POWER USE PLANAR PASSIVATION TYPE
Integrated Gate Bipolar Transistor (IGBT) Modules: 250V

File Size 65.68K  /  5 Page

View it Online

Download Datasheet

    CR02AM-8 CR02AM-8A

MITSUBISHI[Mitsubishi Electric Semiconductor]
Part No. CR02AM-8 CR02AM-8A
OCR Text ...ISTIVE, INDUCTIVE LOADS NATURAL convection 180 0.3 0.4 360 RESISTIVE LOADS 0.5 0.3 0.4 AVERAGE ON-STATE CURRENT (A) AVERAGE ON-STATE CURRENT (A) AVERAGE POWER DISSIPATION (W) ALLOWABLE AMBIENT TEMPERATURE VS. AVERAGE ON-ST...
Description LOW POWER USE GLASS PASSIVATION TYPE

File Size 63.21K  /  5 Page

View it Online

Download Datasheet

    CR02AM CR02 CR02AM-6AB CR02AM-4CA CR02AM-4AB

MITSUBISHI[Mitsubishi Electric Semiconductor]
Part No. CR02AM CR02 CR02AM-6AB CR02AM-4CA CR02AM-4AB
OCR Text ...ISTIVE, INDUCTIVE LOADS NATURAL convection 180 0.3 0.4 360 RESISTIVE LOADS 0.5 0.3 0.4 AVERAGE ON-STATE CURRENT (A) AVERAGE ON-STATE CURRENT (A) AVERAGE POWER DISSIPATION (W) ALLOWABLE AMBIENT TEMPERATURE VS. AVERAGE ON-ST...
Description SCR, TO-92
LOW POWER USE PLANAR PASSIVATION TYPE

File Size 63.07K  /  5 Page

View it Online

Download Datasheet

    CR12AM

MITSUBISHI[Mitsubishi Electric Semiconductor]
Part No. CR12AM
OCR Text ...VE, 120 INDUCTIVE LOADS NATURAL convection MAXIMUM AVERAGE POWER DISSIPATION (SINGLE-PHASE FULL WAVE) 64 56 48 40 32 24 16 8 0 0 4 8 12 = 30 60 180 120 90 360 RESISTIVE LOADS 16 20 24 28 32 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 AVE...
Description MEDIUM POWER USE NON-INSULATED TYPE, GLASS PASSIVATION TYPE

File Size 64.60K  /  6 Page

View it Online

Download Datasheet

For convection conduction Found Datasheets File :: 1709    Search Time::2.719ms    
Page :: | 1 | 2 | 3 | 4 | <5> | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |   

▲Up To Search▲

 




Price and Availability




 
Price & Availability of convection conduction

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X
2.977117061615